نتایج جستجو برای: stereo radiography eos thermoluminescent dosimeter tld
تعداد نتایج: 43006 فیلتر نتایج به سال:
Evaluation of a LiF:Mg,Ti thermoluminescent ring dosimeter according to the IEC 62387:2012 Standards
BACKGROUND Children with lower-limb-length discrepancy require repeated radiographic assessment for monitoring and as a guide for management. The need for accurate assessment of length and alignment is balanced by the need to minimize radiation exposure. We compared the accuracy, reliability, and radiation dose of EOS, a novel low-dose upright biplanar radiographic imaging system, at two differ...
Gamma index pass rates were evaluated for an anthropomorphic phantom using both 2D and 3D calculations. The phantom was irradiated with the traditional dosimetry insert loaded with radiochromic film and TLD, and then with a 3D dosimetry insert. A comparison with the calculated dose distribution showed that both the PRESAGE ® dosimeter and the film and TLD system agreed with the plan to within 5...
Introduction: Becuase of the most radiation dose receiving by human is related to medical radiation exposures, and also Computed Tomography (CT) is a special type of radiography that is one of the main method of radiation exposure today, and it's growing increasingly. Therefore, radio technologists working in CT scan imaging centers, are at risk of radiation. Due to the high am...
The purpose of this study was to evaluate peak skin dose received by the patient and scattered dose to the operator during dual-axis rotational coronary angiography (DARCA), and to compare with those of standard coronary angiography (SA). An anthropomorphic phantom was used to simulate a patient undergoing diagnostic coronary angiography. Cine imaging was applied on the phantom for 2 s, 3 s, an...
The appropriate evaluation of measured doses in mixed fi elds requires the calibration of dosimeters in relation to different types of radiation and exposure conditions in order to split the signal into individual components corresponding to the specifi c radiation and exposure conditions of the entire period and evaluate the critical level, lower limit of detection and corresponding uncertaint...
background: the purpose of this study was to investigate the various gantry angle and ssd dependencies of tld and mosfet dosimeters. materials and methods: lif (mg) tld and mosfet were used in this study. dosimeter systems were calibrated and then irradiated at various gantry angle and ssd by applying 6 mv photon energy. results: based on the results, mosfet changes were found to be in 2% range...
Purpose: We investigated the relationships between patient factors, including obesity, osteopenia, and scoliosis, reliability of measures spinopelvic sagittal parameters using conventional X-radiography (Xp) slot-scanning Xp devices (EOS) examined differences in interobserver measurement them.
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید