نتایج جستجو برای: 192ir

تعداد نتایج: 176  

Journal: :journal of biomedical physics and engineering 0
z. naghshnezhad department of medical radiation engineering, shiraz university, shiraz, iran r. faghihi department of medical radiation engineering, shiraz university, shiraz, iran m. a. mosleh-shirazi center for research in medical physics and biomedical engineering, and department of radiotherapy, shiraz university of medical sciences, shiraz, iran a. s. meigooni comprehensive cancer center of nevada, 3730 s. eastern dr., las vegas, nv, usa

background: the patterson-parker table was created in 1934 to determine mg-hr required to deliver the prescribed dose to the treatment area. these tables were created using the dosimetric data for 226ra that was determined in air and were utilized for dose calculations around implants with ra-equivalent radionuclides such as 137cs and 192ir. therefore, the differences of the tissue attenuation ...

Journal: :iranian journal of radiation research 0
n. babaei bidmeshki department of energy engineering, sharif university of technology, p.o. box 1485893169, tehran, iran m. sohrabpour department of energy engineering, sharif university of technology, p.o. box 1485893169, tehran, iran s.r. mahdavi department of medical physics, faculty of medicine, tehran university of medical sciences p.o. box 1449614525, tehran, iran

background: the purpose of this project was to derive the brachytherapy dosimetric functions described by american association of physicists in medicine (aapm) tg-43 u1 based on high dose rate 192i sources. materials and methods: the method utilized included both simulation of the designed polymethyl methacrylate (pmma) phantom using the monte carlo of mcnp4c and benchmarking of the simulation ...

Journal: :Journal of the Atomic Energy Society of Japan / Atomic Energy Society of Japan 1969

Objective: Brachytherapy sources are widely used for the treatment of cancer. The report of Task Group No. 43 (TG-43) of American Association of Physicists in Medicine is known as the most common method for the determination of dosimetric parameters for brachytherapy sources. The aim of this study is to obtain TG-43 dosimetric parameters for 60Co, 137Cs, 192Ir and 103Pd brachyt...

2010
Michael J. Price Stephen F. Kry Patricia J. Eifel Mohammad Salehpour Firas Mourtada

We conducted a metrological evaluation of the dosimetric impact due to the polysulfone cap used with the Fletcher-Williamson (FW) colpostat for 192Ir high-dose rate and pulsed-dose rate intracavitary brachytherapy using Monte Carlo simulations. Polysulfone caps with diameter of 30 mm, 25 mm, 20 mm, and 16 mm (mini-ovoid) were simulated and the absorbed dose rate in the surrounding water was cal...

A.A. Mowlavi, F. Cupardo, M. Severgnini,

Background: Monte Carlo and experimental relative dose determination in a water phantom, due to a high dose rate (HDR) 192Ir source is presented for real energy spectrum and monochromatic at 356 keV. Materials and Methods: The dose distribution has been calculated around the 192Ir located in the center of 30 cm ×30 cm ×30 cm water phantom using MCNP4C code by Monte Carlo method. Relati...

2016
Navid Ayoobian Akbar Sarabi Asl Hosein Poorbaygi Mohammad Reza Javanshir

High-dose-rate (HDR) brachytherapy is a popular modality for treating cancers of the prostate, cervix, endometrium, breast, skin, bronchus, esophagus, and head and neck as well as soft-tissue sarcomas. Because of different source designs and licensing issues, there is a need for specific dosimetry dataset for each HDR source model. The main objective of the present work is to measure 2D relativ...

2009
Grzegorz Zwierzchowski Barbara Błasiak Patrycja Stefaniak Grzegorz Bielęda

PURPOSE One of the main causes of treatment failures in brachytherapy is incorrect source strength specification in planning system or treatment delivery console. Source strength control is the only scheme to avoid such mistakes. The main aim of this work was to present results of three years of HDR and PDR sources activity control. MATERIAL AND METHODS Study was based on data from 14 192Ir H...

Journal: :Biomedical Journal of Scientific & Technical Research 2018

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید