نتایج جستجو برای: 192ir flexisource
تعداد نتایج: 181 فیلتر نتایج به سال:
PURPOSE The AccuBoost brachytherapy system applies HDR 192Ir beams peripherally to the breast using collimating applicators. The purpose of this study was to benchmark Monte Carlo simulations of the HDR 192Ir source, to dosimetrically characterize the round applicators using established Monte Carlo simulation and radiation measurement techniques and to gather data for clinical use. METHODS Do...
Beam quality correction, kQQ0(r), for solid-state detectors diamond, LiF, Li2B4O7, Al2O3, and plastic scintillator are calculated as a function of distance, r, along the transverse axis of the 60Co and 192Ir brachytherapy sources using the Monte Carlo- based EGSnrc code system. This study also includes calculation of detector-specific phantom scatter correction, kphan(r), for solid phantoms suc...
background: the patterson-parker table was created in 1934 to determine mg-hr required to deliver the prescribed dose to the treatment area. these tables were created using the dosimetric data for 226ra that was determined in air and were utilized for dose calculations around implants with ra-equivalent radionuclides such as 137cs and 192ir. therefore, the differences of the tissue attenuation ...
Objective: Brachytherapy sources are widely used for the treatment of cancer. The report of Task Group No. 43 (TG-43) of American Association of Physicists in Medicine is known as the most common method for the determination of dosimetric parameters for brachytherapy sources. The aim of this study is to obtain TG-43 dosimetric parameters for 60Co, 137Cs, 192Ir and 103Pd brachyt...
We conducted a metrological evaluation of the dosimetric impact due to the polysulfone cap used with the Fletcher-Williamson (FW) colpostat for 192Ir high-dose rate and pulsed-dose rate intracavitary brachytherapy using Monte Carlo simulations. Polysulfone caps with diameter of 30 mm, 25 mm, 20 mm, and 16 mm (mini-ovoid) were simulated and the absorbed dose rate in the surrounding water was cal...
Background: Monte Carlo and experimental relative dose determination in a water phantom, due to a high dose rate (HDR) 192Ir source is presented for real energy spectrum and monochromatic at 356 keV. Materials and Methods: The dose distribution has been calculated around the 192Ir located in the center of 30 cm ×30 cm ×30 cm water phantom using MCNP4C code by Monte Carlo method. Relati...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید