2015
Neisiana Barbieri Denise Piotto Leonardi Marina Samara Baechtold Gisele Maria Correr Marilisa Carneiro Leão Gabardo João César Zielak Flares Baratto-Filho

BACKGROUND The aim of this study was to evaluate the influence of cervical preflaring on apical transportation in curved root canals prepared using the Reciproc and WaveOne reciprocating file systems. METHODS Sixty curved canals were instrumented using Reciproc R25 and WaveOne Primary files, with and without preflaring (n = 15). A double-digital technique was used to digitally superimpose the...

2013
Seyed Mohsen Hasheminia Nastaran Farhadi Ali Shokraneh

The aim of this ex vivo study was to evaluate the effect of using a patency file on apical transportation and curve straightening during canal instrumentation with the ProTaper rotary system. Seventy permanent mandibular first molars with mesiobuccal canals, measuring 18-23 mm in length and with a 25-40° curvature (according to the Schneider method), were selected. The working lengths were dete...

Journal: :iranian endodontic journal 0
kiumars nazari moghaddam shahriar shahab golriz rostami

i ntroduction: the purpose of this in vitro study was to compare the canal transportation and centering ability of twisted file (tf) to that of reciproc system. methods and materials: forty noncalcified roots with mature apices, minimum length of 19 mm and an apical curvature of 15-30 degrees (according to schneider’s method), from freshly extracted mandibular and maxillary teeth, were selected...

Journal: :Australian dental journal 1999
T V Lam D J Lewis D R Atkins R H Macfarlane R M Clarkson M G Whitehead P J Brockhurst A J Moule

The purpose of this project was to observe the amount of apical and mid-curve transportation produced by a range of nickel titanium (NiTi), titanium alloy and stainless steel (SS) files. Tests were carried out in simulated curved root canals produced in epoxy resin blocks. Seven commercially available file types were tested using sizes 15 to 40. Instrumentation was carried out to 1 mm beyond th...

Journal: :Applied sciences 2023

Endodontic shaping can lead to canal and apical anatomical alterations, which may compromise the outcome of root treatment. The objective this systematic literature review is assess whether use martensitic endodontic instruments result in less transportation compared austenitic during therapy. A search was conducted on PubMed, Ovid MEDLINE, Web Science. inclusion criteria were vitro studies com...

2013
Daiana GIANNASTASIO Ricardo Abreu da ROSA Bernardo Urbanetto PERES Mirela Sangoi BARRETO Gustavo Nogara DOTTO Milton Carlos KUGA Jefferson Ricardo PEREIRA Marcus Vinícius Reis SÓ

OBJECTIVE This study has two aims: 1) to evaluate the apical transportation of the Wizard CD Plus and ProTaper Universal after preparation of simulated root canals; 2) to compare, with Adobe Photoshop, the ability of a new software (Regeemy) in superposing and subtracting images. MATERIAL AND METHODS Twenty five simulated root canals in acrylic-resin blocks (with 20º curvature) underwent cone...

Journal: :Journal of endodontics 2014
Dan Zhao Ya Shen Bin Peng Markus Haapasalo

INTRODUCTION The aim of this study was to describe the canal shaping properties of ProTaper Next (PTN; Dentsply Maillefer, Ballaigues, Switzerland), ProTaper Universal (PTU; Dentsply Tulsa Dental Specialties, Johnson City, TN), and WaveOne (Dentsply Maillefer) nickel-titanium instruments in mandibular first molars by using micro-computed tomographic (micro-CT) scanning. METHODS A total of 36 ...

2016
Beatriz Vilas Navós Carolina Bender Hoppe Leticia Boldrin Mestieri Daiana Elizabeth Böttcher Marcus Vinicius Reis Só Fabiana Soares Grecca

CONTEXT One of the goals of endodontic therapy is the shaping and cleaning of the root canal system. In recent years, there has been multiple systems instrumentation, and changes in their dynamics are central to maintain the original shape of the canal after preparation. AIMS The aim of this study was to evaluate centering and transportation in curved root canals after using ProTaper(®) and M...

2012
David Uroz-Torres María Paloma González-Rodríguez Carmen María Ferrer-Luque

Objective: To compare the straightening of root canal curvature, the apical transportation, the loss of working length and the working time using two rotary systems. Study design: Sixty buccal root canals with angles of curvature between 30 to 99o were instrumented with Mtwo and Twisted File rotary instruments. A series of preand post-operative radiographs were superimposed to determine the str...

ژورنال: مجله دندانپزشکی 2008
جوادی‌نژاد, شهرزاد, زارع جهرمی, مریم, میرعنایت, امیرعلی,

Background and Aim: The role of applying rotary instruments in reducing preparation time and proper root canal preparation have been approved in permanent teeth. The aim of this study was to compare the rotary instruments (Hero642) and K-files in root canal preparation of primary molars. Time and canal transportation were compared. Materials and Methods: In this experimental, invitro study, 30...