2003
Habib Zaidi

Reliable attenuation correction methods for quantitative emission CT (ECT) require accurate delineation of the body contour and often necessitate knowledge of internal anatomic structure. Two broad classes of methods have been used to calculate the attenuation map: transmissionless and transmission-based attenuation correction techniques. Whereas calculated attenuation correction belonging to t...

Journal: :Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology 1995
S L Bacharach I Buvat

Quantitation in cardiac positron emission tomography (PET) and single-photon emission computed tomography (SPECT) depends on being able to correct for several physical factors that tend to distort the data. One of the most important of these corrections is the correction for attenuation. For PET, cardiac attenuation correction is a reality, although certain problems remain to be solved. For SPE...

Journal: :Journal of nuclear medicine : official publication, Society of Nuclear Medicine 2003
Habib Zaidi Bruce Hasegawa

Reliable attenuation correction methods for quantitative emission CT (ECT) require accurate delineation of the body contour and often necessitate knowledge of internal anatomic structure. Two broad classes of methods have been used to calculate the attenuation map: transmission-less and transmission-based attenuation correction techniques. Whereas calculated attenuation correction belonging to ...

Journal: :Physics in medicine and biology 2005
Patrick L Chow Fernando R Rannou Arion F Chatziioannou

Attenuation correction is one of the important corrections required for quantitative positron emission tomography (PET). This work will compare the quantitative accuracy of attenuation correction using a simple global scale factor with traditional transmission-based methods acquired either with a small animal PET or a small animal x-ray computed tomography (CT) scanner. Two phantoms (one mouse-...

1993
W. L. S. Costa D. R. Haynor R. M. Haralick T. K. Lewellen

An algorithm for retrospective registration of PET emission and attenuation images is introduced based upon the assumption that no activity should be present outside the body. Since the attenuation image defines anatomy, it is segmented to identify a foreground template of the subject. This template is mapped to the emission image by a geometric transformation, and the emission image pixels tha...

Journal: :Seminars in nuclear medicine 2003
Paul E Kinahan Bruce H Hasegawa Thomas Beyer

A synergy of positron emission tomography (PET)/computed tomography (CT) scanners is the use of the CT data for x-ray-based attenuation correction of the PET emission data. Current methods of measuring transmission use positron sources, gamma-ray sources, or x-ray sources. Each of the types of transmission scans involves different trade-offs of noise versus bias, with positron transmission scan...

Journal: :Journal of nuclear medicine : official publication, Society of Nuclear Medicine 2004
Catalin Loghin Stefano Sdringola K Lance Gould

UNLABELLED Misregistration between attenuation and emission images causes artifactual abnormalities on cardiac PET images that result in false-positive defects. This study determines the frequency and mechanisms of misregistration artifacts, identifies their predictors, and validates a method for their routine clinical identification, prevention, or correction. METHODS We performed 1177 conse...

1999
Ing-Tsung Hsiao Wenli Wang

We introduced [1] a Bayesian method for transmission tomography that used a novel pointwise prior in the form of a mixture of gamma distributions. Here, we compare the performance our pointwise prior with that of a smoothing prior in the context of a weak tumor detection task for emission PET. The reprojected attenuation maps from each method are used for attenuation correction of 2D PET emissi...

Journal: :Medical physics 1998
P E Kinahan D W Townsend T Beyer D Sashin

In this work we demonstrate the proof of principle of CT-based attenuation correction of 3D positron emission tomography (PET) data by using scans of bone and soft tissue equivalent phantoms and scans of humans. This method of attenuation correction is intended for use in a single scanner that combines volume-imaging (3D) PET with x-ray computed tomography (CT) for the purpose of providing accu...

Journal: :International journal of imaging systems and technology 2009
Yan Yan Gengsheng Lawrence Zeng

Quantitative SPECT can be well achieved if photon attenuation is taken into account in the reconstruction process. Using a transmission scan is a common approach. A dramatic simplification could be made if the attenuation map could be obtained from the emission data. In this paper, we propose a new method to estimate the attenuation map using the data consistency conditions of the attenuated Ra...