نتایج جستجو برای: axial compression

تعداد نتایج: 135906  

2017
Muhe Liu Jiliang Liu Guangming Qiu Gang Wang Mingjin Chu

The result showed that the brittle failure was extinct, and the new-type shear walls had good deformability whose ductility factors were over 4.3. The axial compression ratio had significant influence on the mechanical properties of the new-type shear walls. As the increscent of the axial compression ratio, the shear capacity and initial stiffness were improved, but the energy-dissipating capac...

Journal: :Journal of pediatric orthopedics 2004
Andrew T Mahar Steven S Lee Francois D Lalonde Tom Impelluso Peter O Newton

Flexible intramedullary nails are commonly used to treat femoral fractures in children. This study evaluated the biomechanical differences between stainless steel and titanium nails when securing transverse and comminuted fractures in a synthetic femur model. Retrograde flexible stainless steel and titanium nails placed in a divergent "C" pattern were mechanically tested, and axial rotation and...

2017
Jinghao Li John F Hunt Shaoqin Gong Zhiyong Cai

This paper presents experimental results of both quasi-static compression and low-velocity impact behavior for tri-axial bio-composite structural panels using a spherical load head. Panels were made having different core and face configurations. The results showed that panels made having either carbon fiber fabric composite faces or a foam-filled core had significantly improved impact and compr...

Journal: :Physical review. E, Statistical, nonlinear, and soft matter physics 2014
S Neukirch A Antkowiak J-J Marigo

We study the interaction of an elastic beam with a liquid drop in the case where bending and extensional effects are both present. We use a variational approach to derive equilibrium equations and constitutive relation for the beam. This relation is shown to include a term due to surface energy in addition to the classical Young's modulus term, leading to a modification of Hooke's law. At the t...

2006
A. Vaziri

Linear eigenvalue analysis of cracked cylindrical shells under combined internal pressure and axial compression is carried out to study the effect of crack type, size and orientation on the buckling behavior of cylindrical thin shells. Two types of crack are considered; through crack and thumbnail crack. Our calculations indicate that depending on the crack type, length, orientation and the int...

Journal: :international journal of iron & steel society of iran 2011
j. rasti a. najafizadeh m. meratian

in the hot compression test friction has a detrimental influence on the flow stress through the process and therefore, correcting the deformation curve for real behavior is very important for both researchers and engineers. in this study, a series of compression tests were simulated using abaqus software. in this study, it has been employed the taguchi method to design experiments by the factor...

Journal: :مهندسی عمران فردوسی 0
مسعود قادری حسین غفارزاده وحید عرب ملکی

in this paper, a new analytical method is proposed to study the effect of crack and axial load on vibration behavior and stability of the cracked columns. using the local flexibility model, the crack has been simulated by a torsional spring with connecting two segments of column in crack location. by solving governing eigenvalue equation, the effect of crack parameters and axial load on the nat...

2015
Bo Yang

INTRODUCTION: Intervertebral disc experiences large complex deformations including compression, rotation, and bending under daily activity. For example, twisting while carrying a weight, loads the disc under axial compression and axial rotation. Previous work showed that the rate of degeneration and disc injury is higher for in workers that experience repetitive twisting and lifting [1]. Disc d...

Journal: :Veterinary surgery : VS 2014
Lucas H Beierer Mark Glyde Robert E Day Giselle L Hosgood

OBJECTIVE To compare the biomechanical properties of a 10-hole 3.5 mm locking compression plate (LCP) with 2 proximal and 2 distal bicortical locked screws reinforced with either a Steinmann pin of 30-40% the medullary diameter or a poly-ether-ether-ketone (PEEK) rod of ∼75% the medullary diameter in a cadaveric tibia gap model. STUDY DESIGN Ex vivo study. SAMPLE POPULATION Cadaveric canine...

Journal: :ACS applied materials & interfaces 2009
Tao Zhang Junhong Jin Shenglin Yang Guang Li Jianming Jiang

By the introduction of binary hydroxyl groups into poly(p-phenylenebenzoxazole) (PBO) macromolecular chains, a series of dihydroxypoly(p-phenylenebenzobisoxazole) (DHPBO) chains were prepared, and the effect of the hydroxyl groups on the axial compression property of DHPBO fibers was investigated. The variable-temperature Fourier transform infrared spectrum proved the existence of hydrogen bond...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید