Ultrafine-grained pure titanium prepared by equal-channel angular pressing has favorable mechanical performance and does not contain alloy elements that are toxic to the human body. It has potential clinical value in applications such as cardiac valve prostheses, vascular stents, and hip prostheses. To overcome the material's inherent thrombogenicity, surface-coating modification is a crucial p...
Blood compatibility of polyamides has been improved by introducing amido-amine groups in polymer backbone. Polyamide block-copolymer are synthesized by reacting amine end-capped polyamides with N,N'-methylene-bisacrylamide. Polyamide block-copolymers, thus produced found to have the ability of absorbing heparin. Heparinized polyamide block-copolymers have shown significant improvement in blood ...
Although nanotechnology has provided a rich variety of nanomaterials (1-100 nm) for in vivo medical applications, the blood compatibility of all these nanobiomaterials is still largely unexamined. Here, we report the preparation of blood-compatible carbon nanotubes (CNTs) that potentially represent the building blocks for nanodevices having in vivo applications. Activated partial thromboplastin...
Abstract Introduction: As there is a high prevalence of cutaneous Leishmaniasis in Iran, the problems and expenses for culture of the parasite are important. The effect of different types of blood human, cattle, sheep and goat on growth of leishmania tropica promastigote, L.major were examined and compared with rabbit blood. This study was preformed during 2001-2003 in Kashan. Methods: This a...
BACKGROUND Assessment of blood compatibility, typically by tube agglutination (TUBE) and hemolysis crossmatch or, less commonly, by blood typing and alloantibody screening, often is performed before blood transfusion in horses. In contrast, gel column (GEL) and immunochromatographic strip (STRIP) techniques are preferred for compatibility testing in dogs and cats. OBJECTIVE To determine the a...
Blood compatibility of metallocene polyethylene (mPE) was investigated after modifying the surface using hydrochloric acid. Contact angle of the mPE exposed to HCl poses a decrease in its value which indicates increasing wettability and better blood compatibility. Surface of mPE analyzed by using FTIR revealed no significant changes in its functional groups after treatment. Furthermore, scannin...
A wide number of polymers are being used for various medical applications. In this work, microwave-assisted surface modification of metallocene polyethylene (mPE) was studied. FTIR analysis showed no significant changes in the chemical groups after treatment. Contact angle analysis revealed a decrease in contact angle of the treated samples insinuating increasing hydrophilicity and better bioco...