نتایج جستجو برای: cerrobend
تعداد نتایج: 40 فیلتر نتایج به سال:
Mustafa Kamal, Abu-Bakr El-BediwiTamer Dawod* and Adel. S. Waqlan** Metal Physics Lab. Physics Department, Faculty of Science –Mansoura University, Egypt. * Medical Physics Unit, Clinical Oncology and Nuclear Medicine Dept., Faculty of Medicine, Mansoura University **On leave, M.sc student, Ministry of Higher Education, Yemen. [email protected], [email protected] [email protected]...
Background: One of the main causes of induction of secondary cancer in radiation therapy is neutron contamination received by patients during treatment.Objective: In the present study the impact of wedge and block on neutron contamination production is investigated. The evaluations are conducted for a 15 MV Siemens Primus linear accelerator. Methods: Simulations were performed using MCNPX Monte...
background: one of the main causes of induction of secondary cancer in radiation therapy is neutron contamination received by patients during treatment. objective: in the present study the impact of wedge and block on neutron contamination production is investigated. the evaluations are conducted for a 15 mv siemens primus linear accelerator. methods: simulations were performed using mcnpx mon...
background: the shielding methods in radiotherapy due to delivering an accurate radiation dose to cancer tissues and avoiding unnecessary dose to normal tissues are very important. these methods include lead standard blocks, individual molding and multi leaf collimator (mlc). the mlc method is not still common in iran radiotherapy centers. individual molding is better than the lead block shield...
Introduction: Small field dosimetry is challenging for radiotherapy dosimetry. measurement of the output factor in the air and water (Sc, Scp) is one of the input parameters for commissioning of treatment planning systems and beam modeling. The aims of this study are to measured Sc,Scp for small fields with EBT2 and Ion chamber and design a appropriate mini-phantom for small fi...
Background: The Shielding methods in radiotherapy due to delivering an accurate radiation dose to cancer tissues and avoiding unnecessary dose to normal tissues are very important. These methods include Lead standard blocks, individual molding and multi leaf collimator (MLC). The MLC method is not still common in Iran radiotherapy centers. Individual molding is better than the lead block shield...
The aim of this study was to assess the ability of metal artifact reduction (MAR) algorithm in restoring the CT image quality while correcting the tissue density information for the accurate estimation of the absorbed dose. A phantom filled with titanium (low-Z metal) and Cerrobend (high-Z metal) inserts was used for this purpose. The MAR algorithm was applied to phantom's CT dataset. Static in...
In this work, we develop and test a matchline dosimetry analysis tool (MDAT) to examine the dose distribution within the abutment region of two or more adjoining radiotherapy fields that employ different blocking mechanisms and geometries in forming a match. This objective and quantitative tool uses calibrated radiographic film to measure the dose in the abutment region, and uses a frequency di...