نتایج جستجو برای: closed thermosyphon

تعداد نتایج: 121914  

2011
Thanya Parametthanuwat Sampan Rittidech Adisak Pattiya Yulong Ding Sanjeeva Witharana

This article reports a recent study on the application of a two-phase closed thermosyphon (TPCT) in a thermosyphon for economizer (TPEC). The TPEC had three sections of equal size; the evaporator, the adiabatic section, and the condenser, of 250 mm × 250 mm × 250 mm (W × L × H). The TPCT was a steel tube of 12.7-mm ID. The filling ratios chosen to study were 30, 50, and 80% with respect to the ...

A thermosyphon is an efficient heat transfer device, which transports heat using gravity for the evaporation and condensation of the working fluid. In the present study the Box-Benhnken (BBD) design approach was chosen for the Two-Phase Closed Thermosyphon (TPCT) with CeO2 nanofluid using 0.1% volume of Nanofluid with surfactant of ethylene glycol. The experiment resulted in identifying the opt...

Journal: : 2021

The paper provides a review and analysis of research works aimed at studying the factors that affect efficiency reliability closed two-phase thermosyphons as heat utilizers technological emissions. Factors such geometric characteristics their ratio, angles inclination evaporation condensation surfaces, degree filling thermosyphon pipe, state physical properties influence acoustic vibration infl...

2016
Gurtej Singh Lal Kundan Paramjit Singh Bilga R. S. Gaugler T. S. Jadhav M. M. Lele Ryno Laubscher Robert T. Dobson Babek Rashidian

Heat pipe is a device that transports heat with minimal temperature drop using the latent heat of fluid in a closed container. In vertical type named as thermosyphon (Wickless), capillary action is replaced by the gravitational force, this condenser is placed above evaporator. In this paper, to investigate the effect of inlet air temperature and the air mass flow rate was studied. The temperatu...

Journal: :Journal of the Visualization Society of Japan 2005

2012
KAMERON DECKER HARRIS EL HASSAN RIDOUANE DARREN L. HITT CHRISTOPHER M. DANFORTH

A simplified model of natural convection, similar to the Lorenz system, is compared to computational fluid dynamics simulations of a thermosyphon in order to test data assimilation (DA) methods and better understand the dynamics of convection. The thermosyphon is represented by a long time flow simulation, which serves as a reference ‘truth’. Forecasts are then made using the Lorenz-like model ...

2011
M. G. Mousa

In present work a experimental study based on thermosyphon is investigated using a solid nano-particles added to water as a working fluid. Tests are made on a thermosyphon. The experiment was performed in order to measure the temperature distribution and compare the heat transfer rate of the thermosyphon with the nano uid and with pure water. The tested concentration level of the nano-particles...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید