نتایج جستجو برای: coherent light

تعداد نتایج: 450352  

A Sazegarniya A.R Montazer abadi H Esmaeili S.A Ale davood S.M.H Bahreini tosi

Background & Aims: In this study with the aim of benefiting from non-laser sources in photodynamic therapy, photo and radio sensitivity of indocyanine green as a sensitizer in photodynamic and radiation therapies were investigated. Methods: Based on the broad absorption peak of indocyanine green and using non-coherent light, the experiments were performed on human cells derived from breast canc...

Journal: :IEEE Transactions on Aerospace and Electronic Systems 1971

Journal: :The Journal of Physical Chemistry Letters 2018

1995
LÜ Baida

Based on the propagation theory of partially coherent light in the space-frequency domain, the anomalous spectral behavior and spectral switches in the far field of partially coherent and polychromatic light diffracted at an aperture are studied. It is shown that, as compared with spatially fully coherent and polychromatic light whose spectral anomalies are induced only by aperture diffraction,...

2014
E. Bossy

time pressure 2 s R T c  0. 2 P R P r  • Optical detection with a Fabry-Perot • Light wavelength : 670 nm • Ultrasound frequency : 0 ─ 20 MHz • Imaging depth : ~ 6 mm • Resolution : ~ 100 µm • Acquisition time : ~ 15 min Examples of applications: vascularization imaging

2015
William E. White Aymeric Robert Mike Dunne

The Linac Coherent Light Source (LCLS) at the SLAC National Accelerator Laboratory was the first hard X-ray free-electron laser (FEL) to operate as a user facility. After five years of operation, LCLS is now a mature FEL user facility. Our personal views about opportunities and challenges inherent to these unique light sources are discussed.

Journal: :The British journal of ophthalmology 1968
N Manson D Smart H V Ingram

SINCE the advent of laser sources producing coherent light, that is plane polarized and emitted as an almost parallel beam, there has been much conjecture about its use in ophthalmological practice. The human eye, with its clear media capable of refracting a parallel beam to image on the retina, appeared to be the logical target for such a unique source. The tissue reaction consequent to the re...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه صنعتی امیرکبیر(پلی تکنیک تهران) - دانشکده مهندسی 1386

یکی از عواملی که در فرایند تشکیل تصویر سه بعدی در دستگاهای اولتراسوند اختلال ایجاد می کند، نویز لکه ای است. این نویز باعث افت کیفیت بصری تصاویر می شود و تقطیع خودکار حجمهای بدست آمده را دشوار می سازد. تاکنون روشهای متنوعی برای کاهش نویز لکه ای ارایه شده است. برخی از این روشها نیاز به اطلاعات دقیقی از خصوصیات فنی دستگاه تولید کننده تصویر دارند، که این اطلاعات معمولا در دسترس نمی باشد. روشهایی نی...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید