Keith T. Welsh Robert A. Wlodarczyk L. E. Reinstein

The goal of quality assurance (QA) for a radiation oncology medical LINAC is to maintain an acceptable level of equipment performance and reliability. The increasing complexity of Radiation Oncology equipment and treatment techniques have led to increased demands on the work load of the medical physicist. Regular testing needs to be as efficient as possible. Generally, the QA tests, as recommen...

Journal: :Optics express 2012
Jin-Jia Chen Te-Yuan Wang Kuang-Lung Huang Te-Shu Liu Ming-Da Tsai Chin-Tang Lin

We present a simple freeform lens design method for an application to LED collimating illumination. The method is derived from a basic geometric-optics analysis and construction approach. By using this method, a highly collimating lens with LED chip size of 1.0 mm × 1.0 mm and optical simulation efficiency of 86.5% under a view angle of ± 5 deg is constructed. To verify the practical performanc...

2016
Weiliang Du Jennifer L. Johnson Wei Jiang Rajat J. Kudchadker

In Winston-Lutz (WL) tests, the isocenter of a linear accelerator (linac) is determined as the intersection of radiation central axes (CAX) from multiple gantry, collimator, and couch angles. It is well known that the CAX can wobble due to mechanical imperfections of the linac. Previous studies suggested that the wobble varies with gantry and collimator angles. Therefore, the isocenter determin...

2003
I. Zagorodnov T. Weiland

Collimators are used to eliminate halo particles from the beam. To relax the wakefield effects a gradual transition from a large to a small aperture is used. However, the existing computer codes face severe problems for long tapered transitions. Two main sources of the problems are the grid dispersion and the staircase geometry approximation. Using recently developed time domain numerical appro...

Journal: :Physics in medicine and biology 2013
R J Havelin B W Miller H H Barrett L R Furenlid J M Murphy R M Dwyer M J Foley

This work outlines the design and construction of a single-photon emission computed tomography imaging system based on the concept of synthetic collimation. A focused multi-pinhole collimator is constructed using rapid-prototyping and casting techniques. The collimator projects the centre of the field of view (FOV) through 46 pinholes when the detector is adjacent to the collimator, with the nu...

2013
Hirotsugu Kashiwagi Nobumasa Miyawaki Satoshi Kurashima Susumu Okumura

We are developing an acceptance measurement system to evaluate the matching of the emittance of an injection beam to the acceptance of the AVF cyclotron. The system is composed of a phase-space collimator in the low energy section and beam intensity monitors which are installed just after the phase space collimator and in the high energy section. The phase-space collimator, which consists of tw...

Journal: :International Journal of Radiation Oncology*Biology*Physics 2016

Journal: :Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology 2013
Anna Kowalik Marcin Litoborski

BACKGROUND The aim of the modern radiotherapy is to get a homogenous dose distribution in PTV, which is obtained by using for example physical or dynamic wedges. The using of a physical wedge has provided such isodose distributions but their use resulted in detrimental dosimetric consequences, for example beam hardening effects and practical consequences of filter handling or possible misalignm...