نتایج جستجو برای: cone beam ct

تعداد نتایج: 274935  

2016
Ali Zakir Syed LeelaSubhashini Choudary Alluri Dhiraj Mallela Troy Frazee

Concrescence is a form of twinning, formed by the confluence of cementum of two teeth at the root level. The diagnosis of concrescence has largely relied on the conventional 2D imaging. The 2D imaging has inherent limitations such as distortion and superimposition. Cone-Beam CT eliminates these limitations. The aim of this article was to describe a case of dental abnormality using Cone-Beam CT ...

2014
Najmeh Anbiaee Shadi Saghafi Maryam Mohammadzadeh Rezaei

Central granular cell odontogenic tumor) CGCOT) of the jaw is an exceedingly rare benign odontogenic neoplasm with 35 reported cases in the literature. Among these, very few studies have focused on the cone-beam CT features of CGCOT. Here, we report a case of an asymptomatic CGCOT in a 16-year-old girl and focus on the cone-beam CT features. Only 36 cases of this lesion, including this one, hav...

Journal: :International Journal of Radiation Oncology*Biology*Physics 2017

2016
Lawrence Lechuga Georg A. Weidlich

A comparison of image quality and dose delivered between two differing computed tomography (CT) imaging modalities-fan beam and cone beam-was performed. A literature review of quantitative analyses for various image quality aspects such as uniformity, signal-to-noise ratio, artifact presence, spatial resolution, modulation transfer function (MTF), and low contrast resolution was generated. With...

2010
Clemens Maaß Frank Dennerlein Frédéric Noo Marc Kachelrieß

Purpose: With increasing cone angle the cone– beam artifacts in x–ray CT become more and more prominent. It is well known that cone–beam CT (CBCT) does not satisfy the data completeness condition for exact image reconstruction and therefore allows only for approximate image reconstruction [1]. Additionally, in clinical C–arm CT often only a short scan with less than a full rotation can be acqui...

2006
Thomas Flohr Bernd Ohnesorge

3.3 Multi-slice CT Acquisition and Reconstruction for Body Imaging 52 3.3.1 Defi nition of the Pitch 52 3.3.2 The Cone-Angle Problem in Multi-slice CT 53 3.3.3 Multi-slice Spiral Reconstruction Neglecting the Cone-Beam Geometry 54 3.3.3.1 180° and 360° Multi-slice Linear Interpolation 54 3.3.3.2 z-Filter Approaches 56 3.3.4 Multi-slice Spiral Reconstruction with Cone-Beam Algorithms 58 3.3.4.1 ...

Journal: :Journal of oral science 2011
Masao Araki Naoyuki Matsumoto Kunihito Matsumoto Masaaki Ohnishi Kazuya Honda Kazuo Komiyama

Panoramic radiography and cone-beam computed tomography (CT) were used to analyze asymptomatic radiopaque lesions in the jaw bones and determine the diagnostic relevance of the lesions based on their relationships to teeth and site of origin. One hundred radiopaque lesions detected between 1998 and 2002 were examined by both panoramic radiography and cone-beam CT. On the basis of panoramic radi...

Journal: :Medical physics 2007
S A Graham D J Moseley J H Siewerdsen D A Jaffray

The ability of compensators (e.g., bow-tie filters) designed for kV cone-beam computed tomography (CT) to reduce both scatter reaching the detector and dose to the patient is investigated. Scattered x rays reaching the detector are widely recognized as one of the most significant challenges to cone-beam CT imaging performance. With cone-beam CT gaining popularity as a method of guiding treatmen...

2009
Zhye Yin Bruno De Man Jed Pack

A conventional 3rd generation Computed Tomography (CT) system with a single circular source trajectory is limited in terms of longitudinal scan coverage since extending the scan coverage beyond 40 mm results in significant cone-beam artifacts. A multiaxial CT acquisition is achieved by combining multiple sequential 3rd generation axial scans or by performing a single axial multisource CT scan w...

2017
Jasmine A. Oliver Patrick Kelly Sanford L. Meeks Twyla R. Willoughby Amish P. Shah

Purpose To characterize the accuracy of noncoplanar image guided radiation therapy with the Varian Edge radiosurgery system for intracranial stereotactic radiosurgery (SRS) treatments by assessing the accuracy of kV/kV orthogonal pair registration with Optical Surface Monitoring System (OSMS) monitoring relative to cone beam computed tomography (CT). Methods and materials A Computerized Imagi...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید