نتایج جستجو برای: cruciate retaining

تعداد نتایج: 27210  

Journal: :The Journal of bone and joint surgery. British volume 2010
J K Seon S J Park T R Yoon K B Lee E S Moon E K Song

The amount of anteroposterior laxity required for a good range of movement and knee function in a cruciate-retaining total knee replacement (TKR) continues to be debated. We undertook a retrospective study to evaluate the effects of anteroposterior laxity on the range of movement and knee function in 55 patients following the e-motion cruciate-retaining TKR with a minimum follow-up of two years...

Journal: :Joints 2013
Roberto D'Anchise Mauro Andreata Cristiana Balbino Nicola Manta

The debate over the relative merits of substituting or retaining the posterior cruciate ligament in total knee arthroplasty is still ongoing. This article discusses the differences between the two procedures, considering the biomechanics and the surgical techniques involved.

Journal: :Chang Gung medical journal 2004
Ching-Jen Wang Jun-Wen Wang Han-Shiang Chen

BACKGROUND This prospective clinical study was performed to compare the clinical outcomes and radiographic changes between patients with cruciate-retaining (CR) and cruciate-substituting (CS) total knee arthroplasty (TKA). METHODS From 1997 through 1998, 228 patients (183 females and 45 males) with a total of 267 knees with an average age of 55 years (range, 20 to 83 years) were enrolled in t...

Journal: :The Journal of bone and joint surgery. British volume 2008
A Henricson L Linder K G Nilsson

We compared the performance of uncemented trabecular metal tibial components in total knee replacement with that of cemented tibial components in patients younger than 60 years over two years using radiostereophotogrammetric analysis (RSA). A total of 22 consecutive patients (mean age 53 years, 33 to 59, 26 knees) received an uncemented NexGen trabecular metal cruciate-retaining monobloc tibial...

Journal: :The Journal of bone and joint surgery. British volume 2009
T Matsumoto R Kuroda S Kubo H Muratsu K Mizuno M Kurosaka

We have developed a new tensor for total knee replacements which is designed to assist with soft-tissue balancing throughout the full range of movement with a reduced patellofemoral joint. Using this tensor in 40 patients with osteoarthritis we compared the intra-operative joint gap in cruciate-retaining and posterior-stabilised total knee replacements at 0 degrees , 10 degrees , 45 degrees , 9...

Journal: :The Journal of bone and joint surgery. British volume 2004
H Watanabe S Akizuki T Takizawa

We performed a prospective study of 54 patients (76 knees) who underwent Osteonics series 3000 cruciate-retaining cementless total knee arthroplasty between December 1990 and June 1993. Five patients (seven knees) were lost to follow-up (90.7% completion). One patient required revision at 10.5 years after operation. The rate of survival was 100% at ten years and 96.7% at 13 years. The mean ten-...

2010
G Yildirim Walker M Conditt S Horowitz Madrid

The MAKO Surgical Rio Robotic Arm utilizes the pre-op CT images to plan positioning of the uni-condylar and patella-femoral components in order to achieve the most desirable kinematics for the knee joint, while preserving the cruciate ligaments. We hypothesize that the anatomic matching surfaces and the cruciate retaining design of the Restoris knee will best replicate normal knee kinematics. I...

Journal: :Asia-Pacific Journal of Sports Medicine, Arthroscopy, Rehabilitation and Technology 2017

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید