Journal: :iranian journal of radiation research 0
f. bouzarjomehri shahid sadoughi university of medical sciences, yazd, iran m. kiani tabriz university of medical sciences, medical physics, tabriz, iran a.r. farajollahi tabriz university of medical sciences, medical physics, tabriz, iran

background: the shielding methods in radiotherapy due to delivering an accurate radiation dose to cancer tissues and avoiding unnecessary dose to normal tissues are very important. these methods include lead standard blocks, individual molding and multi leaf collimator (mlc). the mlc method is not still common in iran radiotherapy centers. individual molding is better than the lead block shield...

امیرنیا, ایوب, جباری, نصراله, محنتی, پریناز,

Background: Due to the presence of radiosensitive organs in the abdominopelvic region and increasing the number of requests for CT scan examinations, concerns about increasing radiation doses in patients has been greatly elevated. Therefore, the goal of this study was to determine the absorbed dose of radiosensitive organs and the effective dose in patients underwent abdominopelvic CT scan usin...

Objective: Resistance of metastatic lymph nodes (LNs) to high dose I-131 therapy is associated with high morbidity in patients with differentiated thyroid cancer. We evaluated the role of F-18 FDG PET/CT in the prediction of resistance to high dose I-131 therapy in patients with papillary thyroid cancer. Methods: The subjects were 307 patients who underwent total or near total thyroidectomy fol...

Journal: :iranian journal of radiology 0
zahra mahboubifooladi shahid beheshti university of medical sciences, tehran, iran; shahid beheshti university of medical sciences, tehran, iran hooman bahramimotlagh shahid beheshti university of medical sciences, tehran, iran

results the study consisted of 40 patients (all men, with mean age of 33.38 ± 7.4 years). ct evaluation with standard dose were positive in 22 patients (55%). only 1 (2.5%) ct scan assigned as unacceptable by each radiologist in low-dose group. noise average of low-dose protocol, was approximately 7 times greater than standard dose group, while dlp and ed are 9.7 times smaller. in comparison wi...

2014
Paula Duarte Correia Cristiano Roberto Fabri Granzotti Yago da Silva Santos Marco Aurelio Corte Brochi Paulo Mazzoncini de Azevedo-Marques

OBJECTIVE Several studies have been published regarding the use of bismuth shielding to protect the breast in computed tomography (CT) scans and, up to the writing of this article, only one publication about barium shielding was found. The present study was aimed at characterizing, for the first time, a lead breast shielding. MATERIALS AND METHODS The percentage dose reduction and the influen...

ژورنال: سنجش و ایمنی پرتو 2014

The use of computed tomography (CT) as a diagnostic tool has been considerably increased. Therefore, the controlled and protection-based use of the CT scan is necessary to reduce the detrimental effects of radiation. This study was carried out to determine patient dose level in routine CT protocols and measure CTDIW and DLP in routine CT protocols among adult patients in Kashan Shahid Beheshti ...

Introduction: whole body bone scan is one of the most useful procedures of nuclear medicine. Accurate distribution of radiopharmaceutical is yielded by using SPECT-CT. There are concerns about the radiation dose of CT part. The present study aimed to evaluate the patients’ dose in bone nuclear medicine imaging. Methods and Materials: First of all, the dose report of CT console was calibrated u...

2010
Jianwei Gu

There is a serious and growing concern about the CT dose delivered by diagnostic CT examinations or image-guided radiation therapy imaging procedures. To better understand and to accurately quantify radiation dose due to CT imaging, Monte Carlo based CT scanner models are needed. This dissertation describes the development, validation, and application of detailed CT scanner models including a G...

زکریایی, سید سلمان, صبا, ولی اله, ولی زاده, عبدالله,

Introduction: Eye lens is a very sensitive organ to the x-ray radiation and cataract could be formed as a result of eye exposure. Computed tomography (CT) is one of the main exposure sources in clinical situations and brain imaging delivers high amount of exposure to the eye lens. To reduce eye lens dose, efficient dose reduction methods have to be developed and implemented. In this paper, the ...

Journal: :journal of biomedical physics and engineering 0
s zargan department of medical physics, babol university of medical sciences, babol, iran p ghafarian chronic respiratory diseases research center, national research institute of tuberculosis and lung diseases (nritld), shسازمان اصلی تایید شده: دانشگاه علوم پزشکی بابل (babol university of medical sciences)سازمان های دیگر: pet/ct and cyclotron center, masih daneshvari hospital, shahid beheshti university of medical sciences, tehran,

background: pet/ct imaging using [18f]-fdg is utilized in clinical oncology for tumor detecting, staging and responding to therapy procedures. essential consideration must be taken for radiation staff due to high gamma radiation in pet/ct and cyclotron center. the aim of this study was to assess the staff exposure regarding whole body and organ dose and to evaluate environment dose in pet/ct an...