This study presents a modified transient current limiter (MTCL) for mitigation the inrush current of transformers. The MTCL is based on conventional transient current limiter (TCL), which, its configuration is modified to overcome the TCL drawbacks of operation. The proposed MTCL offers lower power losses and voltage/current THD during normal operation mode. It needs only one limiting reactor i...
This paper investigates mitigation of current harmonics using different configuration of cascaded multilevel inverter based shunt hybrid active power filter (SHAPF) and to improve power quality of the system. The main objective of this paper is to develop and analyze the compensation characteristics of cascaded multilevel inverter based shunt hybrid active power filter by employing indirect cur...
A combination of rectifier and DC – DC chopper is useful in feeding DC loads where the DC input to the loads needs to be stepped up or down. Both rectifier and chopper are based on power electronic switches which inject harmonics in the system. This harmonics is an undesirable effect which should be mitigated effectively. For this, passive harmonic filters are used. Passive harmonic filters are...
The power quality issues are of great concern now a days. The increasing use of power electronic devices based nonlinear loads deteriorate the quality of power. Power electronic appliances are widely used in industrial, commercial and utility system thus leading to various power quality problems. This leads to harmonics being injected into the distribution system and also reactive power burden....
We proposed voltage-sourced converter (VSC) with Pulse-width modulation (PWM) provides a faster control that is required for flicker mitigation purpose. The voltage regulation in the distribution feeder is improved by installing a shunt compensator. The proposed DSTATCOM is modeled and its performance is simulated and verified for power factor correction and voltage regulation along with neutra...
Active power filter are been widely used for harmonic elimination. Harmonics are generated by nonlinear load in ac distribution system. The active power filters are broadly classified as shunt active power filter, series active power filter and hybrid filters. With regard to circuit topology, there are two basic kinds of active filter, voltage source and current source. The series active power ...
This paper introduces the indicators for surge arrester condition assessment based on the leakage current analysis. Maximum amplitude of fundamental harmonic of the resistive leakage current, maximum amplitude of third harmonic of the resistive leakage current and maximum amplitude of fundamental harmonic of the capacitive leakage current were used as indicators for surge arrester condition mon...