نتایج جستجو برای: detector response
تعداد نتایج: 1031397 فیلتر نتایج به سال:
In this paper a destriping technique is proposed for pushbroom-type satellite imaging systems. This technique is based on Moment Matching algorithm and assumes a linear response for each detector of imaging system. In the most of the works in this field, the offset parameter in detectors’ response is neglected and images are corrected using only an estimation of gain parameter. Proposed m...
One of the major physics topics of the CBM experiment is the study of the production of open charm in nucleusnucleus collisions at FAIR energies. For this purpose, the CBM Collaboration is planning to use a high-performance Micro-Vertex Detector (MVD) based on Monolithic Active Pixel Sensors (MAPS) [1]. CBM running conditions call for a MVD with high granularity, radiation tolerance, and readou...
This study investigates the fire safety problem of a smoke detection system in terms of the probable response of light scattering photoelectric smoke detectors. In particular, response characteristics of the smoke detectors were studied experimentally in a test chamber described in UL268, with cotton wick generated fire smoke flowing at a velocity between of 0.5 ms and 3 ms. Measurements of a ‘...
Hyphenating High Temperature High Performance Liquid Chromatography (HT-HPLC) with High Temperature Size Exclusion Chromatography (HT-SEC) (High Temperature Two Dimensional Liquid Chromatography (HT-HPLC x HT-SEC or HT 2D-LC)) leads to an isocratic elution in the second dimension, which in turn enables to use IR detector (quantitative detection) for monitoring the eluting polymers. Experimental...
background: radiosurgery is a focal brain irradiation technique that delivers, usually in a single session, high dose of ionizing radiation. the presence of lateral electronic disequilibrium and steep dose gradients in small fields demands special attention to the selection of a suitable detector with respect to its size, composition and response. materials and methods : small circular fields w...
The optomotor response (OMR) is a simple experimental paradigm that is widely used in the study of visual system functions. In the current paper we investigated how spatial and temporal properties of repetitive stimuli determine the OMR in zebrafish. The experiments showed that the OMR has the temporal characteristic of a low-pass filter when the spatial frequencies are low and of a band-pass f...
Many detection methods have been applied to detect radon gas. Due to the low noise and high resolution of gas detectors compared to semiconductor detectors or scintillation detectors, using them to detect alpha radiation is very considerable. Microstrip proportional detector is also included in this group and it has not been used for the detection of radon. In this article, response of the micr...
Abstract—The Spatially Modulated Light CMOS detector (SML CMOS detector) removes the slow part of the current response of a traditional CMOS photodetector, by using the difference between the signals of an immediate and a deferred detector. This slow part of the current response limits the maximum frequency of a photodetector in the conventional CMOS technology to a few MHz. Experimental eviden...
In organic scintillators, the energy distribution of gamma rays and neutrons is indirectly measured by the pulse height distribution of light output produced through gamma ray and neutron reactions in the detectors. Accurate estimate of the interaction of gamma and neutrons in the detector and produce charged secondary particles and subsequent scintillation light produced in the calculation of ...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید