نتایج جستجو برای: diode calibration
تعداد نتایج: 76854 فیلتر نتایج به سال:
ABSTRACT Background: In vivo measurements of applied dose during radiotherapy treatment, is important to ensure accurate dose delivery to patients. Uncertainty in dose delivery should fall within ±5% of the prescribed dose as recommended by ICRU. Assessment of dose for radiotherapy applications performed with various types of detectors. In this study, semiconductor diodes were used which have s...
The dark flux correction step of the Faint Object Spectrograph calibration pipeline was investigated with the joint aims of applying a more physical model and improving the performance of the pipeline. After processing with the original calfos pipeline, dark calibration data shows a large scatter in count rates. We were able to reduce this scatter to some extent by scaling the correction accord...
When photon-counting detectors are calibrated in the presence of a background signal, deadtime effects can be significant and must be carefully accounted for to achieve high accuracy. We present a method for separating the correlated signal from the background signal that appropriately handles deadtime effects. This method includes consideration of pulse timing and afterpulsing issues that aris...
Aquarius is a passive microwave radiometer operating at L-band that is designed to measure ocean salinity. Launched in June 2011, the instrument has since been the subject of on-orbit calibration to evaluate its performance and characterize its stability. This study addresses external calibration methods, using observed antenna temperatures to characterize instrument behavior by computing the o...
A Michelson wavemeter was developed to test the accuracy and give traceability to the wavelength of external cavity diode lasers. These lasers were stabilized using a Littrow configuration and an iodine gas cell as frequency reference, and they were used as light sources in the assembly of a new interferometric system for the gauge block calibration. Previously, a microcontroller counting devic...
Commercially available power meters and sensors have measurement ranges up to several watts. Accurate measurements with these devices require periodic calibration with traceable standards. Conventional calibrations typically take place in the 1mW to 10mW range. This range can be extended downwards for highly sensitive diode sensors by means of a calibrated attenuator. Raising the calibration le...
Faults in photovoltaic (PV) systems, which can result in energy loss, system shutdown or even serious safety breaches, are often difficult to avoid. Fault detection in such systems is imperative to improve their reliability, productivity, safety and efficiency. Here, an innovative model-based fault-detection approach for early detection of shading of PV modules and faults on the direct current ...
abstract background: in vivo measurements of applied dose during radiotherapy treatment, is important to ensure accurate dose delivery to patients. uncertainty in dose delivery should fall within ±5% of the prescribed dose as recommended by icru. assessment of dose for radiotherapy applications performed with various types of detectors. in this study, semiconductor diodes were used which have s...