نتایج جستجو برای: diode dosimeter

تعداد نتایج: 23008  

Journal: :Physics in medicine and biology 2015
T S A Underwood J Thompson L Bird A J D Scott P Patmore H C Winter M A Hill J D Fenwick

Standard commercial diode detectors over-respond within small radiation fields, an effect largely attributable to the relatively high mass-density of silicon. However, Monte Carlo studies can be used to optimise dosimeter designs and have demonstrated that 'mass-density compensation'-for example, introducing a low-density air-gap upstream of a diode's high-density silicon volume-can substantial...

2003
Wanno Lee Bong Jae Lee Chang Woo Lee

Personal dosimeters based on PIN detectors have been widely used because of their simplicity and real time operation. In this paper, the optimal filter thickness and material designed by the Monte Carlo method is 1.0 mm Al plus 0.2 mm Cu. From the results of radiation characteristic analyses, the developed dosimeter has good performance when it is compared with the other conventional those as d...

2007
D. S. McGregor S. Bellinger D. Bruno W. J. McNeil E. Patterson B. B. Rice

Compact neutron detectors are being designed and tested for use as low-power real-time personnel dosimeters. The neutron detectors are pin diodes that are mass produced from high-purity Si wafers. Each detector has thousands of circular perforations etched vertically into the device. The perforations are backfilled with 6 LiF to make the pin diodes sensitive to thermal neutrons. The prototype d...

Journal: :Journal of biomedical optics 2008
Seonkyung Lee Danthu H Vu Michael F Hinds Steven J Davis Alvin Liang Tayyaba Hasan

Photodynamic therapy (PDT) is a promising cancer treatment that involves optical excitation of photosensitizers that promote oxygen molecules to the metastable O(2)(a(1)Delta) state (singlet oxygen). This species is believed to be responsible for the destruction of cancerous cells during PDT. We describe a fiber optic-coupled, pulsed diode laser-based diagnostic for singlet oxygen. We use both ...

2017
Shih-Ming Hsu Chao-Hsiung Hung Yi-Jen Liao Hsiao-Mei Fu Jo-Ting Tsai Yung-Hui Huang David Y. C. Huang

CyberKnife is one of multiple modalities for stereotactic radiosurgery (SRS). Due to the nature of CyberKnife and the characteristics of SRS, dose evaluation of the CyberKnife procedure is critical. A radiophotoluminescent glass dosimeter was used to verify the dose accuracy for the CyberKnife procedure and validate a viable dose verification system for CyberKnife treatment. A radiophotolumines...

2013
T Juang J Newton S Das J Adamovics M Oldham

Deformable 3D dosimeters have potential applications in validating deformable dose mapping algorithms. This study evaluates a novel deformable PRESAGE® dosimeter and its application toward validating the deformable algorithm employed by VelocityAI. The deformable PRESAGE® dosimeter exhibited a linear dose response with a sensitivity of 0.0032 ΔOD/(Gy/cm). Comparison of an experimental dosimeter...

2006
S. Lee D. H. Vu M. F. Hinds S. J. Davis T. Hasan A. Khachemoune W. Rice N. R. Sznycer-Taub

Photodynamic therapy (PDT) is a promising cancer treatment. PDT uses photosensitizers that are selectively retained in malignant tumors. When tumors, pretreated with the photosensitizer, are irradiated with visible light, a photochemical reaction occurs and tumor cells are destroyed. Oxygen molecules in their metastable singlet delta state, O2(∆), are believed to be the species that destroys ca...

2015
Masayori Ishikawa Naomi Nagase Taeko Matsuura Junichi Hiratsuka Ryusuke Suzuki Naoki Miyamoto Kenneth Lee Sutherland Katsuhisa Fujita Hiroki Shirato

The scintillator with optical fiber (SOF) dosimeter consists of a miniature scintillator mounted on the tip of an optical fiber. The scintillator of the current SOF dosimeter is a 1-mm diameter hemisphere. For a scintillation dosimeter coupled with an optical fiber, measurement accuracy is influenced by signals due to Cerenkov radiation in the optical fiber. We have implemented a spectral filte...

Journal: :The Laryngoscope 2015
Stephanie Misono Kathryn Banks Philippe Gaillard George S Goding Bevan Yueh

OBJECTIVES/HYPOTHESIS Voice rest is frequently recommended following surgical disruption of vocal fold epithelium, but patients report variable adherence to voice rest recommendations. The objective of this study was to assess the clinical utility of an ambulatory vocal dosimeter for measuring adherence to voice rest recommendations. STUDY DESIGN Outcomes research. METHODS Part 1: To determ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید