نتایج جستجو برای: dose accuracy dosecalculation algorithms
تعداد نتایج: 933128 فیلتر نتایج به سال:
Background: Inclusion of inhomogeneity corrections in intensity modulated small fields always makes conformal irradiation of lung tumor very complicated in accurate dose delivery.Objective: In the present study, the performance of five algorithms via Monte Carlo, Pencil Beam, Convolution, Fast Superposition and Superposition were evaluated in lung cancer Intensity Modulated Radiotherapy plannin...
Introduction: Each treatment planning algorithm has some errors in dose calculation. Particularly these errors are more pronounced in the heterogeneous regions. It is recommended for each set of radiation data and algorithm subtle deliberation done regarding dose calculation accuracy. Knowing the amount of error in dose calculation will result in a fairly accurate estimate of t...
Introduction Radiotherapy with small fields is used widely in newly developed techniques. Additionally, dose calculation accuracy of treatment planning systems in small fields plays a crucial role in treatment outcome. In the present study, dose calculation accuracy of two commercial treatment planning systems was evaluated against Monte Carlo method. Materials and Methods Siemens Once or linea...
Introduction: Since the delay or mistake in the diagnosis of mood disorders due to the similarity of their symptoms hinders effective treatment, this study aimed to accurately diagnose mood disorders including psychosis, autism, personality disorder, bipolar, depression, and schizophrenia, through modeling and analyzing patients' data. Method: Data collected in this applied developmental resear...
background: in radiation therapy, the peripheral dose is important when anatomical structures with very low dose tolerances are involved. in this study, the two available calculation algorithms of the varian eclipse 8.6 treatment planning system(tps), the anisotropic analytic algorithm (aaa) and pencil-beam convolution (pbc) was used to compare measured and calculated peripheral dose distributi...
background: use of contrast agents (cas) during ct simulation for treatment planing system leads to changes in electron density. in this study we aimed to investigate the effect on calculated dose of various concentrations of cas on treatment planing systems in different dose calculation algorithms. materials and methods: contrast agent (0.769 mg/ml iopromid) - water mixtures at concentration...
Dose calculation algorithms in radiation treatment planning systems (RTPSs) play a crucial role in stereotactic body radiation therapy (SBRT) in the lung with heterogeneous media. This study investigated the performance and accuracy of dose calculation for three algorithms: analytical anisotropic algorithm (AAA), pencil beam convolution (PBC) and Acuros XB (AXB) in Eclipse (Varian Medical Syste...
aims: the aim of the present work is (1) to evaluate dose calculation accuracy of two commonly used algorithms for 15 mv small photon fields in a medium encompassing heterogeneity and (2) compare these results with measured results obtained using gafchromic film ebt2. materials and methods: authors employed kailwood (pinus wallichiana) to mimic lung. briefly, seven kailwood plates, each measuri...
Introduction: Since the delay or mistake in the diagnosis of mood disorders due to the similarity of their symptoms hinders effective treatment, this study aimed to accurately diagnose mood disorders including psychosis, autism, personality disorder, bipolar, depression, and schizophrenia, through modeling and analyzing patients' data. Method: Data collected in this applied developmental resear...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید