an important need in radiation therapy is a fast and accurate treatment planning system. this system using ct data and characteristics of the radiation beam, calculates the dose in all points of the patient’s volume. two main factors in planning system are “accuracy” and “speed”. according to these factors, various generation of treatment planning systems are developed.   this article is the re...

Daryoush Shahbazi Gahrouei Mohammad B. Tavakoli Mojtaba Karbalee

Introduction: An accurate and fast radiation dose calculation is essential for successful radiation radiotherapy. The aim of this study was to implement a new graphic processing unit (GPU) based radiation therapy treatment planning for accurate and fast dose calculation in radiotherapy centers. Materials and Methods: A program was written for parallel runnin...

2016
Shohei Mizutani Yoshihisa Takada Ryosuke Kohno Kenji Hotta Ryohei Tansho Tetsuo Akimoto

Full Monte Carlo (FMC) calculation of dose distribution has been recognized to have superior accuracy, compared with the pencil beam algorithm (PBA). However, since the FMC methods require long calculation time, it is difficult to apply them to routine treatment planning at present. In order to improve the situation, a simplified Monte Carlo (SMC) method has been introduced to the dose kernel c...

2006
H. Iwase

A calculation of activation and induced dose spatial distribution caused by 1.5 GeV/u U irradiation was carried out for the design of the shielding of the Super-FRS[1], which is under development for the future project at FAIR GSI. The calculation is based on a model newly developed in this study and it is divided into; (1) Residual nuclei calculation (2) activation calculation, (3) dose conver...

Hassan Ali Nedaie, Mahbod Esfahani Nasibeh Kavousi Somayeh Gholami,

Introduction: In radiation therapy, the accuracy of dose calculations by a treatment planning system (TPS) is important to achieve tumor control and to spare normal tissue. Treatment planning system calculations in the heterogeneous situation may present significant inaccuracies. In this study, three different dose calculation algorithms, pencil beam (PB), collapsed cone (CC), ...

Introduction: Computerized treatment planning is a rapidly evolving modality that depends on hardware and software efficiency. Despite ICRU recommendations suggesting 5% deviation in dose delivery the overall uncertainty shall be less than 3.5% as suggested by B.J. Minjnheer. J. In house spreadsheets are developed by the medical physicists to cross-verify the dose calculated by the Treatment Pl...

Journal: :iranian journal of nuclear medicine 2007
ali shabestani monfared mehrangiz amiri

introduction: radioactive materials deliver internal radiation dose to patients in nuclear medicine. manual internal radiation dose assessment is a complicated method. introduction of a simple dose calculation software is the main goal of the present study. methods: using the best current data in internal dose calculation (s-factors) recommended by icrp and by considering other technical metho...