نتایج جستجو برای: dose rate and radiation source

تعداد نتایج: 17000624  

Background: Hot lab is a specially designed room in a nuclear medicine hospital where the radiopharmaceuticals are delivered, stored and prepared for dispensing. 99Mo/99mTc-generator is the major source in the hot lab used for various medical imaging. It is important to maintain a standard for hot lab procedures to optimize the patient care and minimize radiation exposure to all nuclear medicin...

Journal: :iranian journal of medical physics 0
hassan ali nedaie radiotherapy oncology department, cancer research center, cancer institute, tehran university of medical sciences, tehran, iran. nooshin banaee young researchers and elites club, science and research branch, islamic azad university, tehran, iran.

introduction intensity-modulated radiotherapy (imrt) is becoming an increasingly routine treatment method. imrt can be delivered by use of conventional multileaf collimators (mlcs) and/or physical compensators. one of the most important factors in selecting an appropriate imrt technique is integral dose. integral dose is equal to the mean energy deposited in the total irradiated volume of the p...

Journal: :iranian journal of radiation research 0
s. sina radiation research center, school of engineering, shiraz university, shiraz, iran r. faghihi radiation research center, school of engineering, shiraz university, shiraz, iran a.s. meigooni department of radiation medicine, university of kentucky medical centre, lexington, kentucky, usa s. mehdizadeh radiation research center, school of engineering, shiraz university, shiraz, iran m. zehtabian radiation medicine department, school of engineering, shiraz university, shiraz, iran m.a. mosleh-shirazi radiotherapy physics unit, department of radiotherapy and oncology, shiraz university of medical sciences, shiraz, iran

background: the dose rate distribution delivered by a low dose rate 137cs pellet source, a spherical source used within the source trains of the selectron gynecological brachytherapy system, was investigated using the mcnp4c monte carlo code. materials and methods: the calculations were performed in both water and plexiglas and the absolute dose rate distribution for a single pellet source and ...

ژورنال: :فیزیک زمین و فضا 2012
سمیه رستمی مهربان مرتضی فتاحی فرانک بحرالعلومی

while a crystalline material is heated from room temperature to around 500°c, a weak but measurable light will be emitted. this light is known as thermoluminescence (tl) and is based on storage of energy from ionizing radiation in many naturally occurring tl minerals, including quartz and feldspar. the source of radiation is the radioactive materials such as uranium, thorium, potassium and cosm...

ژورنال: سنجش و ایمنی پرتو 2020

Brachytherapy, is a method to treat prostate cancer in which a radiation source is placed inside or next to the cancer affected tissues. Purpose of this article is to determine the uncertainty level of received dose in prostate tissue due to the relocation of the placed radiation sources and inflation in prostate after positioning the radiation seeds. To simulate the model 6711 Amersham (activi...

Journal: :iranian journal of nuclear medicine 2002
simin dadashzadeh golahmad nasiroghli ali sattari

patients receiving diagnostic doses of radiopharmaceuticals become a source of contamination and exposure for those who come in contact with them, such as nuclear medicine technologists, relatives and nurses. therefore, the measurement of external radiation dose from these patients is necessary. in this study, the dose rates at distances of 10, 50 and 100cm from 70 patients who received diagnos...

اسلامی, اکبر, سقطچی, فرانک, صلوتی, مجتبی,

Background and Objective: Due to importance of ionizing radiation on human health, many studies have been performed to measure the background gamma radiation all around the world as well as some cities in lran. This study was carried out to measure the amount of background gamma radiation in outdoor areas in different seasons in Zanjan to determine the annual effective dose of the city resident...

M. Sadeghi, O. Kiavar,

Background: Recently, different investigators have studied the possibility of radiation therapy in restenosis prevention and have shown promising results. In this study a unique radioactive source for intra vascular brachytherapy (IVBT) was investigated. The two-dimensional dose distribution in water for a 32P IVBT stent has been calculated. The pure beta emitter source 32P has been co...

K. Kant, M. Garg, R. Kumari,

Background: Natural radionuclides in rock samples, primarily 238U (uranium), 232Th (thorium) and 40K (potassium), are the main source of radiation exposure to workers and general public and their measurement is of paramount importance from radiation protection point of view. Materials and Methods: Gamma spectrometry using HPGe detector was used to measure the radioactivity and assess the radiol...

Journal: :archives of cardiovascular imaging 0
benjamin s goins brooke army medical center, cardiology section, texas, usa aaron henderson hematology and oncology department, brooke army medical center, san antonio, texas, usa charles k lin brooke army medical center, cardiology section, texas, usa anthony charmforoush department of medicine, brooke army medical center, san antonio, texas, usa takor b arrey-mbi department of medicine, brooke army medical center, san antonio, texas, usa ryan l prentice brooke army medical center, cardiology section, texas, usa

patients and methods we evaluated radiation exposure from initial and downstream testing in a prospectively collected, matched cohort evaluated for cp in the emergency department (ed) with either ccta compared with usual care over a median follow-up of 19.6 months. effective radiation dose was calculated using published conversion factors. results prospective, ecg-triggered acquisition using a ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید