نتایج جستجو برای: energy fluence

تعداد نتایج: 669012  

2014
Mohamed K. Metwally Sherif H. El-Gohary Kyung Min Byun Seung Moo Han Soo Yeol Lee Min Hyoung Cho Jinsung Cho

Photoacoustic imaging (PAI) is a non-invasive and non-ionizing imaging modality that combines the absorption contrast of light with ultrasound resolution. Laser is used to deposit optical energy into a target (i.e., optical fluence). Consequently, the target temperature rises, and then thermal expansion occurs that leads to generating a PA signal. In general, most image reconstruction algorithm...

2018
Lian-Kuang Lim Seong-Ling Yap D A Bradley

The plasma focus device discussed herein is a Z-pinch pulsed-plasma arrangement. In this, the plasma is heated and compressed into a cylindrical column, producing a typical density of > 1025 particles/m3 and a temperature of (1-3) × 107 oC. The plasma focus has been widely investigated as a radiation source, including as ion-beams, electron-beams and as a source of x-ray and neutron production,...

2003
David S. Followill Marilyn S. Stovall Stephen F. Kry Geoffrey S. Ibbott

The shielding calculations for high energy (>10 MV) linear accelerators must include the photoneutron production within the head of the accelerator. Procedures have been described to calculate the treatment room door shielding based on the neutron source strength (Q value) for a specific accelerator and energy combination. Unfortunately, there is currently little data in the literature stating ...

2005
Z. Bosnjak A. Celotti F. Longo G. Barbiellini

Recently proposed correlations between the energetics of Gamma-Ray Bursts (GRB) and their spectral properties, namely the peak energy of their prompt emission, are found to account for the observed fluence distribution of all ‘bright’ BATSE GRB. Furthermore for an intrinsic GRB peak energy distribution extending toward lower energies with respect to that characterizing bright GRB, such correlat...

Journal: :Medical physics 2005
Michael K Fix Paul J Keall Jeffrey V Siebers

One limitation to the widespread implementation of Monte Carlo (MC) patient dose-calculation algorithms for radiotherapy is the lack of a general and accurate source model of the accelerator radiation source. Our aim in this work is to investigate the sensitivity of the photon-beam subsource distributions in a MC source model (with target, primary collimator, and flattening filter photon subsou...

تحصیلداران‌فرد, فاطمه‌السادات, فرهبد, امیرحسین,

An analytical model for two-pass optical amplifier with arbitrary beams overlap has been developed which generalized the classical theory of Frantz-Nodvik for single pass amplifier. The effect of counterpropagating beams on gain and output energy fluence included in the model. Moreover, the appropriate limiting relations for two special cases of weak input signal and saturation state of the amp...

Journal: :iranian journal of radiation research 0
h. ghiasi medical physics department, medical school, tabriz university of medical sciences, tabriz, iran a. mesbahi radiation oncology department, imam hospital, daneshgah street, tabriz, iran

background: the characteristics of secondary neutrons in a high energy radiation therapy room were studied using the mcnpx monte carlo (mc) code. materials and methods: two mc models including a model with full description of head components and a simplified model used in previous studies were implemented for mc simulations. results: results showed 4-53% difference between full and with the sim...

A. Mesbahi, H. Ghiasi,

Background: The characteristics of secondary neutrons in a high energy radiation therapy room were studied using the MCNPX Monte Carlo (MC) code. Materials and Methods: Two MC models including a model with full description of head components and a simplified model used in previous studies were implemented for MC simulations. Results: Results showed 4-53% difference between full and wit...

2015
B. E. Carlson N. Østgaard P. Kochkin Ø. Grondahl R. Nisi K. Weber Z. Scherrer K. LeCaptain

X-ray emission by sparks implies bremsstrahlung from a population of energetic electrons, but the details of this process remain a mystery. We present detailed statistical analysis of X-ray spectra detected by multiple detectors during sparks produced by 1 MV negative high-voltage pulses with 1 μs risetime. With over 900 shots, we statistically analyze the signals, assuming that the distributio...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید