نتایج جستجو برای: filtered backprojection contrast to noise ratio

تعداد نتایج: 10727429  

Journal: :Journal of nuclear medicine technology 2013
Gengsheng L Zeng

Iterative maximum-likelihood expectation maximization and ordered-subset expectation maximization algorithms are excellent for image reconstruction and usually provide better images than filtered backprojection (FBP). Recently, an FBP algorithm able to incorporate noise weighting during reconstruction was developed. This paper compares the performance of the noise-weighted FBP algorithm and the...

Byeongil Lee Hee-Seung Bom Hyeon Sik Kim Ju Han Kim, Sang-Geon Cho, Seong Young Kwon,

Objective(s): In order to evaluate the effect of post-reconstruction Gaussian filtering on image quality and myocardial blood flow (MBF) measurement by dynamic N-13 ammonia positron emission tomography (PET), we compared various reconstruction and filtering methods with image characteristics. Methods: Dynamic PET images of three patients with coronary artery disease (male-female ratio of 2:1; a...

2014
Akihiro Haga Keiichi Nakagawa Calvin Maurer Ken Ruchala Edward Chao Dylan Casey Satoshi Kida Dousatsu Sakata Masahiro Nakano Taiki Magome Yoshitaka Masutani

PURPOSE TomoTherapy (Accuray Co.) has an image-guided radiotherapy system with megavoltage (MV) X-ray source and the on-board imaging device. With the MV computed tomography (MVCT), it became feasible to perform the efficient daily-3D registration of the patient position before each treatment delivery. This system also allows one to acquire the delivery sinogram during the actual treatment, whi...

Journal: :Medical physics 2014
Gengsheng L Zeng

PURPOSE The purpose of this paper is to implement a noise-weighted filtered backprojection (FBP) algorithm in the form of "convolution" backprojection, but this "convolution" has a spatially variant integration kernel. METHODS Noise-weighted FBP algorithms have been developed in recent years, with filtering being performed in the Fourier domain. The noise weighting makes the ramp filter in th...

Ahmad Mostaar, Mahmoud Shiri Seyed Mohsen Sadat-Shahabi Zahra Mansouri

Introduction: Measurement of the complex 3D radiation dose distribution created with advanced radiotherapy techniques such as IMRT and SRS became very important. Polymer gel dosimetry (PGD) is proposed method to recording this dose distribution. MRI, X-ray CT, ultrasound, spectrophotometry and optical CT scanners can be used for readout of Polymer gel dosimeters. Although MRI i...

Journal: :Journal of cardiovascular computed tomography 2009
James K Min Rajesh V Swaminathan Melissa Vass Scott Gallagher Jonathan W Weinsaft

BACKGROUND The assessment of coronary stents with present-generation 64-detector row computed tomography scanners that use filtered backprojection and operating at standard definition of 0.5-0.75 mm (standard definition, SDCT) is limited by imaging artifacts and noise. OBJECTIVES We evaluated the performance of a novel, high-definition 64-slice CT scanner (HDCT), with improved spatial resolut...

Journal: :Medical physics 2013
Gengsheng L Zeng Alex Zamyatin

PURPOSE This paper derives a ray-by-ray weighted filtered backprojection (rFBP) algorithm, based on our recently developed view-by-view weighted, filtered backprojection (vFBP) algorithm. METHODS The rFBP algorithm directly extends the vFBP algorithm by letting the noise weighting vary from channel to channel within each view. The projection data can be weighted in inverse proportion to their...

2007
T. P. Trouard J. W. Totenhagen A. Bilgin

Introduction Radial fast spin-echo (Radial-FSE) methods have been used to produce high-resolution diffusion-weighted images that are insensitive to motion and/or magnetic field inhomogeneity [1,2]. However, one of the drawbacks of radial-FSE is the long acquisition time, compared to single shot echo planar imaging, required for high resolution images with sufficient signal to noise ratio (SNR)....

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید