To meet the strict criteria of grid codes for the integrated wind farm with the grid has become a major point of concern for engineers and researchers today. Moreover voltage stability is a key factor for the stable operation of grid connected wind farm during fault ride through and grid disturbances. This paper investigates the implementation and comparison of FACTS devices like STATCOM and SV...
The fault recovery of VSC-HVDC transmission system is often influenced by many factors, such as the reactive power compensation characteristics of the inverter and the dynamic performance of DC controllers. In this paper, the PSCAD/ EMTDC simulation tool is used to study the dynamic recovery performance of VSC-HVDC system for several different var compensating devices in VSC-HVDC inverter-Fixed...
This paper presents, “Performance Analysis of power flow control through FACTS Devices in Power System. In a power system network consisting of generators, transmission lines, transformers and load etc., STATCOM, SVC and UPFC are applied between two buses separately and their effects are analyzed as par applied system conditions. Power flow between different buses and voltage regulation of abov...
This project proposes a voltage stability for an interline photovoltaic (I-PV) system. In an I-PV system, the inverters in a PV plant are reconfigured in such a way that two or more distribution networks / feeder are interconnected. The I-PV system is operated as a flexible ac transmission system (FACTS) device STATCOM to regulate the point of common coupling voltage on either feeder. One of th...
This report concentrates on presenting transient stability and power ow models of Thyristor Controlled Reactor (TCR) and Voltage Sourced Inverter (VSI) based Flexible AC Transmission System (FACTS) Controllers. Appropriate models for voltage and angle stability studies are discussed in detail for the Static Var Compensator (SVC), the Thyristor Controlled Series Compensator (TCSC), the Static Va...
FACTS tools in modern power systems provide a vital solution to the problems of voltage deviation and fault ride-through (FRT) capability electrical especially during integration wind power. Many distinct journals highlight that wind-driven squirrel cage generator (SCIG) still accounts for around 15% operating generators so far. To enhance stability FRT capacity, this paper recommends cost-effe...
An ABB SVC Light® rated at 13.2 kV, 0-64 Mvar (capacitive) has been installed at the Gerdau plant in Charlotte, N.C., USA operating an electric arc furnace (EAF) with continuous charging for scrap-based steel production. The EAF, rated at 30/33 MVA, as well as a ladle furnace (LF) rated at 18 MVA are taking their power from a 100 kV supply grid. The fast control of SVC Light will improve the po...
A constant worldwide growing load stress over a power system compelled the practice of reactive injection to ensure an efficient network. For this purpose, multiple technologies exist in knowledge market out which paper emphasizes usage flexible alternating current transmission (FACTS) and presents comparative study static var compensator (SVC) with synchronous (STATCOM), inducted real electric...