نتایج جستجو برای: graft coated stent

تعداد نتایج: 160975  

2014
Young Il Kim Young Ho Choi Jin Wook Chung Hyo-Cheol Kim Young Ho So Hyun Beom Kim Seung-Kee Min Jae Hyung Park

OBJECTIVE We evaluated the effect of close contact between the stent and the graft on the induction of endothelial covering on the stent graft placed over an aneurysm. MATERIALS AND METHODS Saccular abdominal aortic aneurysms were made with Dacron patch in eight dogs. The stent graft consisted of an inner stent, a expanded polytetrafluoroethylene graft, and an outer stent. After sacrificing t...

M. Sadeghi, O. Kiavar,

Background: Recently, different investigators have studied the possibility of radiation therapy in restenosis prevention and have shown promising results. In this study a unique radioactive source for intra vascular brachytherapy (IVBT) was investigated. The two-dimensional dose distribution in water for a 32P IVBT stent has been calculated. The pure beta emitter source 32P has been co...

2011
Kyung Seob Lim Young Joon Hong Daisuke Hachinohe Khurshid Ahmed Myung Ho Jeong Jung Ha Kim Doo Sun Sim Min Goo Lee Keun-Ho Park Ju Han Kim Youngkeun Ahn Jeong Gwan Cho Jong Chun Park Sun-Jung Song Kyoung Woon Jung Dong Lyun Cho Jung Chaee Kang

BACKGROUND AND OBJECTIVES The aim of this study was to examine the anti-proliferative and anti-inflammatory effects of a stent coated with abciximab and alpha-lipoic acid (ALA) in a porcine coronary overstretch restenosis model. MATERIALS AND METHODS A total of 10 pigs were randomized into two groups (10 pigs, 10 coronaries in each group) in which the coronary arteries were stented with a dua...

Journal: :Interactive cardiovascular and thoracic surgery 2009
Shang Dong Xu Bao Zhong Yang Zhan Ming Fan Fang Jiong Huang

Open stent-graft has been used in the treatment of aortic dissection in recent years. Two device related complications happened in two patients. One was stenosis of the true lumen in the descending aorta caused by infolding of the distal end of the stent-graft immediately after its deployment. The other one was a new intima tear at the distal end of the stent-graft caused by full expansion of t...

Journal: :CVIR Endovascular 2021

Abstract Background A tracheo-innominate fistula is a rare but life-threatening complication of tracheostomy and has mortality rate 100% without therapy. The underlying cause an acquired between the brachiocephalic trunk trachea, induced by cannula’s mechanical impact. Case presentation 25-year-old female was admitted with pulsatile bleeding from tracheostomy. artery fistula, which difficult to...

Journal: :Journal of vascular surgery 1999
C K Zarins R A White D Schwarten E Kinney E B Diethrich K J Hodgson T J Fogarty

The results of a prospective, nonrandomized, multicenter clinical trial that compared endovascular stent graft exclusion of abdominal aortic aneurysms with open surgical repair are presented. During an 18-month period, 250 patients with infrarenal aneurysms underwent treatment at 12 study sites-190 patients underwent endovascular repair using the Medtronic AneuRx stent graft (Sunnyvale, Calif),...

2014
Liang-Wan Chen Xi-Jie Wu Xiao-Fu Dai Lin Lu Dong-Shan Liao Chao Li Qian-Zhen Li

BACKGROUND In total arch repair with open placement of a triple-branched stent graft for acute type A aortic dissection, the diameters of the native arch vessels and the distances between 2 neighboring arch vessels did not always match the available sizes of the triple-branched stent grafts, and insertion of the triple-branched stent graft through the distal ascending aortic incision was not ea...

2017
In-Ho Bae Myung Ho Jeong Ju Han Kim Yong Hwan Park Kyung Seob Lim Dae Sung Park Jae Won Shim Jung Ha Kim Youngkeun Ahn Young Joon Hong Doo Sun Sim

BACKGROUND AND OBJECTIVES Hyaluronic acid (HA) is highly biocompatible with cells and the extracellular matrix. In contrast to degradation products of a synthetic polymer, degradation products of HA do not acidify the local environment. The aim of this study was to fabricate an HA-coated paclitaxel (PTX)-eluting stent via simple ionic interactions and to evaluate its effects in vitro and in viv...

2012
Xiaoning Sun Shuyang Lu Shouguo Yang Hao Lai Hao Chen Tao Hong Chunsheng Wang

BACKGROUND The primary experience of open triple-branched stent graft placement for acute aortic arch dissection was reported. METHODS Between January 2011 and October 2011, 13 well-selected patients (mea age, 46±8.2 years; approximate range, 30~58 years) with acute aortic arch dissection underwent open triple-branched stent graft placement for total arch reconstruction. The triple-branched s...

Journal: :Croatian medical journal 2007
Maja Strozzi Darko Anić

AIM To compare polytetrafluoroethylene stent graft (PTFE) with sirolimus and bare metal stents in reducing in-stent restenosis in native coronary vessels in patients with acute coronary syndrome. METHODS The study included patients who underwent stent implantation in acute coronary syndrome from January 2003 to May 2004. The patients (n=119) were randomized either to stent graft group (n=40),...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید