نتایج جستجو برای: heat gain

تعداد نتایج: 366158  

This experiment was carried out to investigate the effects of different levels chromium picolinate (CrPic) and chromium nanoparticles (nano-Cr) on the performance and immune function of broilers under heat stress condition. A total of 320 Ross 308 broiler chicks (from 21 to 42 days) were assigned randomly into eight treatment groups (four replicates per treatment, and 10 chicks per replicate) a...

Journal: :Physical review. E 2016
Artem Ryabov Viktor Holubec

We discuss the efficiency of a heat engine operating in a nonequilibrium steady state maintained by two heat reservoirs. Within the general framework of linear irreversible thermodynamics we derive a universal upper bound on the efficiency of the engine operating at arbitrary fixed power. Furthermore, we show that a slight decrease of the power below its maximal value can lead to a significant ...

2006
Jeffrey D. Spitler Daniel E. Fisher

The radiant time series method is a new method for performing design cooling load calculations, derived from the heat balance method. It effectively replaces all other simplified (non-heat-balance) methods such as the cool#zg load temperature difference~solar cooling load~cooling load factor method (CLTD/SCL/CLF), the total equivalent temperature difference~time averaging method (TETD/TA), and ...

2013
Mansour Nikpour Mohd Zin Kandar Elaheh Mousavi

In order for using building simulation tools, validation of building simulation should be evaluated. Integrated Environmental Solution (IES) is an environmental design tool which couples an intuitive 3-dimensional modeling interface with extensive performance analysis function covering different criteria such as day lighting, heat gain and energy. The validity of IES ha...

جعفری آهنگری, یوسف, حسنی, سعید , دستار, بهروز , هاشمی, سید رضا ,

This experiment was conducted to compare the effect of trimethylglycine supplementation in diets with sufficient or insufficient quantities of protein on blood electrolytes and lipid concentrations in broilers subjected to heat stress condition. Ross 308 broilers were fed with four dietary treatments from 21 to 42 d of age. The treatments consisted of a diet with sufficient levels of protein (...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه صنعتی اصفهان 1389

run-out-table (rot) is located between last finishing stand and down coiler in a hot strip mill. as the hot steel strip passes from rot, water jets impact on it from top and bottom and strip temperature decreases approximately from 800-950 °c to 500-750°c. the temperature history that strip experience while passing through rot affects significantly the metallurgical and mechanical properties, s...

2014
Xudong Wang Yunho Hwang Reinhard Radermacher Xudong WANG Yunho HWANG Reinhard RADERMACHER Hung M. PHAM

An 11 kW R410A heat pump system with a two-stage vapor-injected scroll compressor has been developed and tested. A conventional heat pump system with a scroll compressor having the same displacement volume to the vapor-injected scroll compressor has been tested under the same conditions to serve as a baseline. The vaporinjected scroll compressor has been tested with the cycle options of both fl...

Journal: :Poultry science 2003
P K Liew I Zulkifli M Hair-Bejo A R Omar D A Israf

The effects of early age feed restriction and heat conditioning on heat shock protein (HSP) 70 expression, antibody production, resistance to infectious bursal disease (IBD), and growth of heat-stressed male broiler chickens were investigated. Chicks were divided into 4 groups: 60% feed restriction on d 4,5, and 6 (FR); exposure to 36 +/- 1 degrees C for 1 h from d 1 to 21 (HT); combination of ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید