نتایج جستجو برای: holladay ii formulas
تعداد نتایج: 611618 فیلتر نتایج به سال:
Aims: To study the refractive outcome of cataract surgery employing IOLMaster biometry data and to compare it with that of applanation ultrasonography in a prospective study of 100 eyes that underwent phacoemulsification with intraocular lens implantation. Methods: The Holladay formula using IOLMaster data was employed for the prediction of implanted intraocular lenses (IOLs). One month after c...
AIMS To study the refractive outcome of cataract surgery employing IOLMaster biometry data and to compare it with that of applanation ultrasonography in a prospective study of 100 eyes that underwent phacoemulsification with intraocular lens implantation. METHODS The Holladay formula using IOLMaster data was employed for the prediction of implanted intraocular lenses (IOLs). One month after c...
PURPOSE To investigate the accuracy of a new optical biometer for intraocular lens (IOL) power calculation in eyes undergoing cataract surgery. METHODS Consecutive eyes of patients undergoing cataract surgery with the same IOL model were enrolled in a prospective cohort study. Axial length (AL) and corneal power were measured with an optical biometer based on optical low-coherence interferome...
INTRODUCTION Selection of an appropriately-powered IOL is a complex issue, especially in eyes with an axial length of less than 20 mm in pediatric cataract. OBJECTIVE To assess the accuracy of IOL power calculation formulae in pediatric cataracts in eyes with an axial length of less than 20 mm. MATERIALS AND METHODS The records of children less than 15 years old with congenital cataract who...
AIM To evaluate the prediction error in intraocular lens (IOL) power calculation for a rotationally asymmetric refractive multifocal IOL and the impact on this error of the optimization of the keratometric estimation of the corneal power and the prediction of the effective lens position (ELP). METHODS Retrospective study including a total of 25 eyes of 13 patients (age, 50 to 83y) with previo...
PURPOSE To compare accuracy of intraocular lens (IOL) power calculation formulae in infantile eyes with primary IOL implantation. DESIGN Comparative case series. METHODS The Hoffer Q, Holladay 1, Holladay 2, Sanders-Retzlaff-Kraff (SRK) II, and Sanders-Retzlaff-Kraff theoretic (SRK/T) formulae were used to calculate predicted postoperative refraction for eyes that received primary IOL impla...
BACKGROUND Despite growing number of intraocular lens power calculation formulas, there is no evidence that these formulas have good predictive accuracy in pediatric, whose eyes are still undergoing rapid growth and refractive changes. This study is intended to compare the prediction error and the accuracy of predictability of intraocular lens power calculation in pediatric patients at 3 month ...
PURPOSE To assess the refractive change and prediction error after temporary intraocular lens (IOL) removal in temporary polypseudophakic eyes using IOL power calculation formulas and Gills' formula. METHODS Four consecutive patients (7 eyes) who underwent temporary IOL explantation were enrolled. Postoperative refractions calculated using IOL power calculation formulas (SRK-II, SRK-T, Hoffer...
Purpose. This study aims to compare the accuracy of intraocular lens power calculation formulas in eyes with long axial lengths from Chinese patients subjected to cataract surgery. Methods. A total of 148 eyes with an axial length of >26 mm from 148 patients who underwent phacoemulsification with intraocular lens implantation were included. The Haigis, Hoffer Q, Holladay 1, and SRK/T formulas w...
OBJECTIVES To compare anterior chamber depth (ACD) changes after phacoemulsification surgery in patients with pseudoexfoliation syndrome (PEX) and normal patients using an anterior segment imaging method. Another aim of this study was to evaluate the effect of these changes on the accuracy of intraocular lens (IOL) power calculation and postoperative refraction. MATERIALS AND METHODS Twenty-t...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید