نتایج جستجو برای: keratometer

تعداد نتایج: 98  

2011
Hasan Razmju Leila Rezaei Kobra Nasrollahi Hamid Fesharaki Hossein Attarzadeh Farhad Janbaz Footami

PURPOSE To compare keratometric measurements using a Javal type manual keratometer with IOLMaster in eyes undergoing photorefractive keratectomy (PRK) for myopia. METHODS In this comparative case series, we studied patients aged 21 to 27 years scheduled for myopic PRK. Keratometry was performed preoperatively and three months after the procedure using a Javal type manual keratometer and the I...

Journal: :Journal of Korean Ophthalmic Optics Society 2013

Journal: :Journal of American Association for Pediatric Ophthalmology and Strabismus 2011

Journal: :The British journal of ophthalmology 1953
A SORSBY M SHERIDAN

MANY studies have been made of the changes of refraction of the eye during infancy and childhood, but little is known of the changes in the individual components of total refraction. Such changes must be of considerable magnitude to compensate for the axial elongation of the globe during growth, for the refraction of the adult eye with its longer axis differs but little from that seen in early ...

Journal: :The British journal of ophthalmology 2002
J Santodomingo-Rubido E A H Mallen B Gilmartin J S Wolffsohn

BACKGROUND A new commercially available device (IOLMaster, Zeiss Instruments) provides high resolution non-contact measurements of axial length (using partial coherent interferometry), anterior chamber depth, and corneal radius (using image analysis). The study evaluates the validity and repeatability of these measurements and compares the findings with those obtained from instrumentation curre...

2002
J Santodomingo-Rubido J S Wolffsohn

Background: A new commercially available device (IOLMaster, Zeiss Instruments) provides high resolution non-contact measurements of axial length (using partial coherent interferometry), anterior chamber depth, and corneal radius (using image analysis). The study evaluates the validity and repeatability of these measurements and compares the findings with those obtained from instrumentation curr...

Journal: :The British journal of ophthalmology 1990
P S Raj T Akingbehin A M Levy

Automated refraction with the Canon RK-1 Autoref keratometer was evaluated in 110 eyes (110 patients) six to eight weeks after they had undergone extracapsular cataract extraction with posterior chamber intraocular lens implantation and achieved a best corrected visual acuity of at least 6/12. Autorefraction readings were obtained in 100 (91%) of these eyes. The agreement between autorefraction...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید