نتایج جستجو برای: kvp accuracy
تعداد نتایج: 336094 فیلتر نتایج به سال:
introduction quality control (qc) techniques are used in monitoring and maintenance of the components of an x-ray system. qc of radiology devices plays a significant role in reduction of medication dose and optimization of image quality. this study aimed to conduct qc tests on randomly selected radiology devices, installed in diagnostic imaging departments of iran. materials and methods in tota...
OBJECTIVES The purpose of this study was to assess image quality and radiation dose of lower extremity CT angiography (CTA) with 70 kVp, high pitch acquisition and sinogram-affirmed iterative reconstruction (SAFIRE). METHODS Lower extremity CTAs were performed on 44 patients: 22 patients were examined using protocol A (120 kVp, pitch of 0.85 and 120 ml of contrast agent on a first-generation ...
Head computed tomography (CT) plays an important role in the comprehensive evaluation of acute stroke. Photon-counting spectral detectors, as promising candidates for use in the next generation of x-ray CT systems, allow for assigning more weight to low-energy x-rays that generally contain more contrast information. Most importantly, the spectral information can be utilized to decompose the ori...
Introduction Using ionization radiation for diagnostic and treatment fields has increased worldwide dramatically. This issue causes an increase in the absorbed and collective doses in society noticeably. With regard to two main principles in radiation protection, i.e., justification and optimization, it is necessary to have imaging process with minimum dose to patients and personnel. For achiev...
The purpose of this article is to evaluate image quality and radiation dose of prospectively electrocardiogram (ECG)-triggered high-pitch coronary computed tomography angiography (CCTA) at 70 kVp and 30 mL contrast medium.One hundred fifty patients with a heart rate ≤70 beats per minute (bpm) underwent CCTA using a second-generation dual-source computed tomography (CT) scanner and were randomiz...
OBJECTIVE This study was conducted to assess the feasibility of performing 100-kVp electrocardiogram (ECG)-gated coronary CT angiography, as compared to 120-kVp ECG-gated coronary CT angiography. MATERIALS AND METHODS We retrospectively evaluated one hundred eighty five gender- and body mass index-matched 16-slice coronary CT sets of data, which were obtained using either 100 kVp and 620 effe...
OBJECTIVE To compare the image quality of shoulder CT arthrography performed using 120 kVp and 140 kVp protocols. MATERIALS AND METHODS Fifty-four CT examinations were prospectively included. CT scans were performed on each patient at 120 kVp and 140 kVp; other scanning parameters were kept constant. Image qualities were qualitatively and quantitatively compared with respect to noise, contras...
BACKGROUND In radiotherapy treatment planning, intravenous administration of an iodine-based contrast agent during computed tomography (CT) improves the accuracy of delineating target volumes. However, increased tissue attenuation resulting from the high atomic number of iodine may result in erroneous dose calculations because the contrast agent is absent during the actual procedure. The purpos...
Quality assurance (QA) of the image quality for image-guided localization systems is crucial to ensure accurate visualization and localization of target volumes. In this study, a methodology was developed to assess and evaluate the constancy of the high-contrast spatial resolution, dose, energy, contrast, and geometrical accuracy of the BrainLAB ExacTrac system. An in-house fixation device was ...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید