نتایج جستجو برای: mass attenuation coefficient
تعداد نتایج: 679612 فیلتر نتایج به سال:
normal 0 false false false en-us x-none ar-sa aim: ct number (hu) and linear attenuation coefficient contain useful information which can be determined during usual ct scanning for the prediction of breast cancerous cells existence based on hemoglobin concentration. methods: this study used breast phantom containing major and minor vessels with diameters of 10 and 5 mm, respectively. the major...
This paper presents the precise method to estimate the dependence of linear and mass attenuation coefficients of gamma rays on concentration of Manganese (II) chloride (MnCl2). The experiment was done using GSpec gamma spectroscopy system. The GSpec consists 2‖x 2‖ NaI (Tl) detector with Multichannel analyzer (MCA). The GSpec has built in 14 Pin PMT base.The GSPEC is pc based Gamma Ray Spectros...
introduction: the photoelectric attenuation coefficient of substances is known to depend upon the energy e of the photon and the effective atomic number of substances (zeff) as (zeff x /e y ). no definitive values about these indices x, y are given in the literature. the index x is said to lie between, 3.0 and 4.0, while for ‘y’ different values have been assigned, between 3.0 and 4.0. methodo...
background: radiation shielding properties is an important for a material wish can be used the photon attenuation coefficients of clay produced using different rate of boron have been measured for the purpose of radioactive waste disposal. materials and methods: the measurement has been performed using gamma spectrometer contains nai (tl) detector at the photon energies of 662, 1173 and 1332 ke...
The limiting uncertainty in recent high accuracy measurements of the mass attenuation coefficient is the measurement of the integrated column density. An improvement in the design of the absorption foil holder is described which reduces the integrated column density uncertainty. The new design allows the edges of the foil to be more accurately mapped by the X-ray beam by reducing the largest so...
An extension of the X-ray extended-range technique is described for measuring X-ray mass attenuation coefficients by introducing absolute measurement of a number of foils - the multiple independent foil technique. Illustrating the technique with the results of measurements for gold in the 38-50 keV energy range, it is shown that its use enables selection of the most uniform and well defined of ...
The variation in mass attenuation coefficient μ for total and partial photon interaction processes for three different oxide glasses (65CaO-35Al2O3(OG1) , 20Na2O-80SiO2(OG2), and 20Na2O-5Al2O3-75SiO2 (OG3)), in the incident energy range from 10 keV to 100 GeV has been studied using software package XCOM and the effect of chemical composition on the values of μ is also interpreted graphically. M...
Background: In this study, a method for linear attenuation coefficient calculation was introduced.Methods: Linear attenuation coefficient was calculated with a new method that base on the physics of interaction of photon with matter, mathematical calculation and x-ray spectrum consideration. The calculation was done for Cerrobend as a common radiotherapy modifier and Mercury.Results: The values...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید