The characteristics of local heat transfer and pressure drop were investigated experimentally for the vertical up-flow boiling of refrigerant R1234yf in two types of aluminum multi-port extruded tubes having 16 channels with a crosssection of 0.91 × 0.21 mm (tube A) and 40 channels with a cross-section of 0.34 × 0.21 mm (tube B). At an evaporating temperature of 15 °C, the local heat transfer c...
in the present paper, an analysis was carried out to investigate effects of radiation on a free convection flow bounded by a vertical surface embedded in a porous medium with constant suction velocity. it was under the influence of uniform magnetic field in the presence of a homogenous chemical reaction and viscous dissipation with constant heat and mass flux. the non-dimensional governing equa...
nucleate pool boiling heat transfer coefficient have been experimentally measured on a horizontal rod heater for various liquid binary mixtures. measurements are based on more than three hundred data points on a wide range of concentrations and heat fluxes. in this investigation, it has been confirmed that the heat transfer coefficient in boiling solutions are regularly less than those in pure ...
This paper deals with an experimental study on the frosting phenomena using a fin bundle, which is an expanded model for the fins of the heat exchanger. The overall characteristics such as total frost mass, mass flux, pressure drop, sensible and latent heat fluxes and the local characteristics such as local temperature, local heat flux and local frost thickness were investigated under several e...
In conventional intermittent hemodialysis, the overall mass transfer coefficient (Kd) of a dialyser is mostly calculated at zero ultrafiltration and at relatively high dialysate flow rates. In continuous arterio-venous hemodiafiltration (CAVHD), the dialysate flow rates are low as comparable to the rates of ultrafiltration flows, making the dialysis treatment as slow as possible. Therefore the ...
Experimental study of flow boiling heat transfer in a microchannel array consisting of main channels connected to two auxiliary channels (each) was conducted. A microbubble-excited actuation mechanism, powered by high frequency vapor bubble growth and collapse, was established to create and sustain strong mixing in the microchannels. It was shown to significantly enhance flow boiling heat trans...
BACKGROUND In comparison to conventional haemodialysis membranes, highly permeable membranes allow a broader spectrum of solute removal, including enhanced elimination of vancomycin (1448 Daltons). However, the mass transfer characteristics of vancomycin removal by highly permeable membranes have not been adequately assessed. An understanding of vancomycin's predominant dialytic mass transfer m...
Calcium alginate membrane has great potential for membrane separation technology. The polymer frameworks of the membrane were successfully regulated by the mass fraction of homopolymeric blocks of -L-guluronic acid (FGG) in the entire molecular chain of alginate and the additive CaCl2 as a cross-linker. The mechanical strength can be controlled by regulated the FGG and CaCl2 concentration. Sele...
the paper aims at investigating the effects of chemical reaction and thermal radiation on the steady two-dimensional laminar flow of viscous incompressible electrically conducting micropolar fluid past a stretching surface embedded in a non-darcian porous medium. the radiative heat flux is assumed to follow rosseland approximation. the governing equations of momentum, angular momentum, energy, ...