نتایج جستجو برای: mcnp code

تعداد نتایج: 168334  

Journal: :iranian journal of radiology 0
lida gholamkar department of medical radiation engineering, science and research branch, islamic azad university, tehran, iran ali asghar mowlavi physics department, hakim sabzevari university, sabzevar, iran; international center for theoretical physics (ictp), associate federation scheme, medical physics field, trieste, italy; physics department, hakim sabzevari university, sabzevar, iran. tel: +98-5144012521 mahdi sadeghi radiation application research school, nuclear science and technology research institute, tehran, iran mitra athari department of medical radiation engineering, science and research branch, islamic azad university, tehran, iran

conclusion by comparing the results, we saw that w/rh anode/filter combination is the best choice in breast mammography imaging because of the lowest delivered dose in comparison with w/ag and rh/al. moreover, breast thickness and g value have significant effects on mgd. objectives the aim of this study was to determine the average absorbed dose of x-ray radiation in the glandular tissue of the...

Journal: :iranian journal of medical physics 0
vahid moslemi m.sc. in medical radiation engineering, medical radiation dept., faculty of mechanical engineering, shiraz university, shiraz, iran ahmad esmaili-torshabi m.sc. in medical radiation engineering, medical radiation dept., faculty of mechanical engineering, shiraz university, shiraz, iran mohammad amin mosleh-shirazi assistant professor, radiotherapy and oncology dept., center of research in medical physics and engineering, shiraz university of medical sciences, shiraz, iran reza faghihi assistant professor, nuclear engineering, center of radiation research, shiraz university, shiraz, iran ahmad mosalaei professor, radiotherapy and oncology dept., shiraz university of medical sciences, shiraz, iran simin mehdizadeh m.sc., nuclear engineering, center of radiation research, shiraz university, shiraz, iran

introduction: in brachytherapy, radioactive sources are placed close to the tumor, therefore, small changes in their positions can cause large changes in the dose distribution. this emphasizes the need for computerized treatment planning. the usual method for treatment planning of cervix brachytherapy uses conventional radiographs in the manchester system. nowadays, because of their advantages ...

As the input of MCNP code (Monte Carlo N - Particle code system), a monoenergetic and isotropic point source with the energy rangeg from 0.3 to 10 MeV was placed at the center of a spherical material surrounded by another one. The first shielding material was water and the second one was lead. The total thickness of the shield varied between 2 to 10 mfp. Then, using the output of MCNCP, exposur...

2012
Matthew R. Halstead Sangjin Lee James Petrosky Abigail Bickley Paul Sokol

The energy spectrum of the Neutron Radiation Effects Program (NREP) beam line, Target-ModeratorReflector-1 (TMR-1), at Indiana University has not been previously characterized. The facility has a unique proton source with variable pulse length (15-600 s) and energy (13 MeV). Thus, it can produce a unique and tailored neutron beam when incident on a beryllium target. Through a combination of MCN...

2012
Craig M. Marianno Sunil S. Chirayath William S. Charlton Sunil P. Khatri Yassin A. Hassan Sunil S Chirayath Sunil Chirayath

Radiation Transport Simulation Studies Using MCNP for a Cow Phantom to Determine an Optimal Detector Configuration for a New Livestock Portal. (August 2012) Joe Justina, M.Sc., Mangalore University Co-Chairs of Advisory Committee: Dr. Craig M. Marianno Dr. Sunil S. Chirayath A large radiological accident will result in the contamination of surrounding people, animal, vegetation etc. In such a s...

Journal: :Arab Journal of Nuclear Sciences and Applications 2018

Journal: :iranian journal of radiation research 0
t.p. faez physical oceanography department, azad university, tehran, iran s. sarkar department of medical physics, tehran university of medical sciences, tehran, iran

abstract

2015
Tran Van Hung

---------------------------------------------------------------------***--------------------------------------------------------------------Abstract The dose distribution in irradiation room and the dose rate at each dwell position of 60Co irradiator SVST-Co-60/B have been calculated using MCNP code. The calculated results are useful information to estimate radiation safety and design irradiato...

Journal: :journal of medical signals and sensors 0
daryoush shahbazi-gahrouei saba ayat

introduction: radioiodine therapy is an effective method for treating thyroid cancer carcinoma, but it has some affects on normal tissues, hence dosimetry of vital organs are important to weigh the risks and benefits of this method. the aim of this study is to measure the absorbed doses of important organs by mcnp (monte carlo n particle) simulation and comparing the results of different method...

D. Rezaei Ochbelagh, H. Miri Hakimabad, R. Izadi Najafabadi,

Background: Several landmine detection methods, based on nuclear techniques, have been suggested during the recent years. Neutron energy moderation, neutron-induced gamma emission, neutron and gamma attenuation, and fast neutron backscattering are nuclear-based methods used for landmine detection. The aim of this study is to use backscattered neutron for landmine detection. Materials ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید