نتایج جستجو برای: mcnp4b

تعداد نتایج: 30  

Journal: :Physics in medicine and biology 2002
Indrin J Chetty Jean M Moran Teamor S Nurushev Daniel L McShan Benedick A Fraass Scott J Wilderman Alex F Bielajew

A comprehensive set of measurements and calculations has been conducted to investigate the accuracy of the Dose Planning Method (DPM) Monte Carlo code for electron beam dose calculations in heterogeneous media. Measurements were made using 10 MeV and 50 MeV minimally scattered, uncollimated electron beams from a racetrack microtron. Source distributions for the Monte Carlo calculations were rec...

2005
W. S. Kiger

NATIONAL LABORATOR Y Los Alamos National Laborato ry, an affirmative action/equal opportunity employer, is operated by the University of California for the U .S . Depa rtment of Energy under contract W -7405-ENG-36 . By acceptance of this art icle, the publisher recognizes that the U .S. Government retains a nonexclusive, royalty-free license to publish or reproduce the published form of this c...

Journal: :Medical physics 2002
J T Goorley W S Kiger R G Zamenhof

As clinical trials of Neutron Capture Therapy (NCT) are initiated in the U.S. and other countries, new treatment planning codes are being developed to calculate detailed dose distributions in patient-specific models. The thorough evaluation and comparison of treatment planning codes is a critical step toward the eventual standardization of dosimetry, which, in turn, is an essential element for ...

حسین غفوریان حسین پوربیگی, شهاب شیبانی, محمدرضا قهرمانی

استفاده از بالون آنژیوپلاستی حاوی مایع رادیوآکتیو اخیراً به عنوان یک تکنیک جدید برای کاستن عود تنگی عروق، پیشنهاد شده است. اندازه‌گیری توزیع دْز در اطراف بالون آن‍‍ژیوپلاستی پر شده با Re-perhenate186 با استفاده از فیلم رادیوکرومیک انجام گرفت. نرخ دْز اندازه‌گیری شده در فاصله 0.4  میلی‌متری از سطح بالون (با قطر 4 میلی‌متر و طول 40 میلی‌متر) برابر با مقدار [(cGy/min)/(mCi/ml)] 2.07  بود. ...

2001
U. Beifuss M. F. McNitt-Gray J. J. DeMarco C. H. Cagnon Michael McNitt-Gray

This study is designed to accurately simulate a helical CT-scanner for the purpose of estimating radiation dose and to perform validation experiments involving several dose profile and ionization chamber measurements. To accomplish this we have modified a general purpose Monte Carlo transport code (MCNP4B) as the framework for simulating the x-ray source and its movement, photon transport and r...

Journal: :iranian journal of radiation research 0
h. nedaie department of medical physics, tehran university of medical sciences, tehran, iran m. shariary department of nuclear engineering, shahid beheshti university, tehran, iran h. gharaati department of medical physics, tehran university of medical sciences, tehran, iran m. allahverdi department of medical physics, tehran university of medical sciences, tehran, iran m.a. mosleh-shirazi joint department of physics, royal marsden hospital and institute of cancer research, surrey, uk

abstract background: accurate methods of radiation therapy dose calculation. there are different monte carlo codesfor simulation of photons, electrons and the coupled transport of electrons and photons. mcnpis a general purpose monte carlo code that can be used for electron, photon and coupledphoton-electron transport.monte carlo simulation of radiation transport is considered to be one of the ...

H. Gharaati, H. Nedaie, M. Allahverdi, M. Shariary, M.A. Mosleh-Shirazi,

ABSTRACT Background: accurate methods of radiation therapy dose calculation. There are different Monte Carlo codesfor simulation of photons, electrons and the coupled transport of electrons and photons. MCNPis a general purpose Monte Carlo code that can be used for electron, photon and coupledphoton-electron transport.Monte Carlo simulation of radiation transport is considered to be one of the ...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه کاشان - دانشکده علوم 1384

از آنجایی که راکتور یکی از زایاترین منابع تولید نوترون است، لذا لازم است که همیشه برای حفظ سلامت نه تنها افراد بلکه محیط از نظر میزان دز نوترون تحت کنترل باشد. در این پایان نامه بنا به اهمیت موضوع، ما روی میزان دز نوترون در اطراف راکتور صفر قدرت اصفهان مطالعه و اندازه گیری انجام داده ایم تا از سلامت افرادی که در آنجا کار می کنند مطمین شویم.

Journal: :iranian journal of radiation research 0
h. pourbeigi department of nuclear research center, atomic energy organization of iran, tehran, iran h. ghafourian a.s. meigooni m. taghizadeh-asl a.r. ghahremani

background: recent pre-clinical and clinical studies indicate that irradiation in the dose range of 15 to 30 gy can reduce rate of restenosis in patients who have undergone an angioplasty. the use of filled balloon with radioactive solution was proposed as one of the possible intravascular irradiation techniques. materials and methods: the monte carlo n-particle transport code (mcnp4b) was used...

A.R. Ghahremani, A.S. Meigooni, H. Ghafourian, H. Pourbeigi, M. Taghizadeh-asl,

Background: Recent pre-clinical and clinical studies indicate that irradiation in the dose range of 15 to 30 Gy can reduce rate of restenosis in patients who have undergone an angioplasty. The use of filled balloon with radioactive solution was proposed as one of the possible intravascular irradiation techniques. Materials and Methods: The Monte Carlo N-particle Transport Code (MCNP4b) was used...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید