Journal: :iranian journal of radiation research 0
a. mostaar medical physics department, tehran university of medical sciences, tehran, iran m. allahverdi department of radiotherapy physics, cancer institute, tehran, iran m. shahriari gamma irradiation center, atomic energy organization of iran, tehran, iran

background: in treating patients with radiation, the degree of accuracy for the delivery of tumor dose is recommended to be within ± 5% by icru in report 24. the experimental studies have shown that the presence of low-density inhomogeneity in areas such as the lung can lead to a greater than 30% change in the water dose data. therefore, inhomogeneity corrections should be used in treatment pla...

Journal: :iranian red crescent medical journal 0
sedigheh sina radiation research center, shiraz university, shiraz, ir iran reza faghihi radiation research center, shiraz university, shiraz, ir iran; department of nuclear engineering, shiraz university, shiraz, ir iran; radiation research center, shiraz university, shiraz, ir iran. tel: +98-7116473474, fax: +98-7116473474 ali soleimani meigooni department of nuclear engineering, shiraz university, shiraz, ir iran; comprehensive cancer center of nevada, las vegas, nevada, usa zahra siavashpour department of radiation medicine, shahid beheshti university, tehran, ir iran mohammad amin mosleh-shirazi center for research in medical physics and biomedical engineering, shiraz university of medical sciences, shiraz, ir iran; department of radiotherapy and oncology, shiraz university of medical sciences, shiraz, ir iran

conclusions according to the results, the old dosimetry formalisms, overestimate the dose especially towards the applicator’s tip. while the tg-43u1 based software perform the calculations more accurately. results for a typical arrangement of 10 active pellets in the applicator, the percentage difference between doses obtained by the new algorithm at 1cm distance from the tip of the applicator ...

Journal: :international journal of advanced biological and biomedical research 2013
mohammad mirzaei

large quantities of radiopharmaceuticals prescribed for treatment and diagnosis are excreted through kidney. therefore, radiation unwanted dose is created in kidney. as a result, exact calculation of prescribed radiopharmaceuticals amount is important. monte carlo method is used for simulation of radiation transport in body due to random nature of radiation. in this research, for the first time...

Abdolazim Sedighi Alireza Khoshghadam Mohammad Hadi Gholami, Mohammad Mohammadi,

Introduction: Because of importance of impact of the Source to Surface Distance (SSD) in determining of monitor unit for electron-therapy, it is essential to know the Virtual Source Position (VSP) for electron beam for a linear therapeutic accelerator for each energy and field size. , especially using the Khan method (photo distance squared method) And compare the results with...

Journal: :journal of biomedical physics and engineering 0
s a rahimi tarbiat modares university b hashemi tarbiat modares university s r mahdavi iran university of medical sciences

background: estimating dosimetric parameters for small fields under non-reference conditions leads to significant errors if done based on conventional protocols used for large fields in reference conditions. hence, further correction factors have been introduced to take into account the influence of spectral quality changes when various detectors are used in non-reference conditions at differen...

2011
Hiroaki KUMADA Takeji SAKAE Kimiaki SAITO Tomonori ISOBE Takayuki HASHIMOTO Hideyuki SAKURAI

In proton radiotherapy, a proton generates secondary neutrons and photons in a patient’s body. This leads to irradiation of the area in proximity to the target region with incidental doses caused by secondary radiation in addition to the therapeutic dose. However in current treatment planning of proton radiotherapy, conventional dose estimation algorithms like the pencil beam method can not est...

M. Aliakbar-Golkar, Y. Raisee-Gahrooyi,

This paper compares fault position and Monte Carlo methods as the most common methods in stochastic assessment of voltage sags. To compare their abilities, symmetrical and unsymmetrical faults with different probability distribution of fault positions along the lines are applied in a test system. The voltage sag magnitude in different nodes of test system is calculated. The problem with the...

M C Pant M L B Bhatt, M Shajahan N Jamal N Painuly, N Singh, S Mishra T Verma

Background: Inclusion of inhomogeneity corrections in intensity modulated small fields always makes conformal irradiation of lung tumor very complicated in accurate dose delivery.Objective: In the present study, the performance of five algorithms via Monte Carlo, Pencil Beam, Convolution, Fast Superposition and Superposition were evaluated in lung cancer Intensity Modulated Radiotherapy plannin...

Journal: :iranian journal of medical physics 0
asghar mesbahi department ofmedical physics, medical school, tabriz university of medical sciences,,tabriz, iran. 2- department ofradiation oncology, imam hospital, tabriz, iran. ismail zergoug 3-department of radiotherapy, emir abdelkaderanti-cancer center, oran, algeria

introduction radiotherapy with small fields is used widely in newly developed techniques. additionally, dose calculation accuracy of treatment planning systems in small fields plays a crucial role in treatment outcome. in the present study, dose calculation accuracy of two commercial treatment planning systems was evaluated against monte carlo method. materials and methods siemens once or linea...