نتایج جستجو برای: monte carlo polymer gel radiotherapy

تعداد نتایج: 326301  

آقامیری, سید محمود رضا, باغانی, حمیدرضا, حیدرلو, نعمت‌الله, مهدوی, سید ربیع,

Intraoperative electron radiotherapy is one of the radiotherapy methods that delivers a high single fraction of radiation dose to the patient in one session during the surgery. Beam shaper applicator is one of the applicators that is recently employed with this radiotherapy method. This applicator has a considerable application in treatment of large tumors. In this study, the dosimetric charact...

A. Amouheidari, M. Atarod, P. Shokrani,

Background: The aim of this study was to develop and implement a Monte Carlo framework for evaluation of patient specific out-of-field organ equivalent dose (OED). Materials and Methods: Dose calculations were performed using a Monte Carlo-based model of Oncor linac and tomographic phantoms. Monte Carlo simulations were performed using EGSnrc user codes. Dose measurements were performed using r...

Journal: :iranian journal of medical physics 0
seyed mostafa ghavami department of radiology, paramedical school, tabriz university of medical sciences, tabriz, iran hosein ghiasi medical radiation sciences research team, tabriz university of medical sciences tabriz, iran

introduction accurate estimation of the skin-absorbed dose in external radiation therapy is essential to estimating the probability of secondary carcinogenesis induction materials and methods electron contamination in prostate radiotherapy was investigated using the monte carlo (mc) code calculation. in addition, field size dependence of the skin dose was assessed. excess cancer risk induced by...

Abolfazl Mahmoodi Hossein Tavakoli-Anbaran,

Introduction: Radiotherapy involves all methods that can provide a special amount of ionizing radiation to malignant tissue with the assumption that minimal damage to healthy tissues is achieved. We are looking for a valuable and reliable method to measure the absorption dose and also the ability to measure the absorption dose distribution in three dimensions, which today is th...

Journal: :journal of biomedical physics and engineering 0
t r verma king george medical university,up;lucknow n k painuly king george medical university, up, lucknow, indiaسازمان اصلی تایید شده: 0 دانشگاه های خارج از کشور s p mishra سازمان اصلی تایید شده: 0 دانشگاه های خارج از کشور m shajahan n singh king george medical university, up, lucknow, india m l b bhatt dr.ram manohar lohia institute of medical sciences, lucknow, indiaسازمان اصلی تایید شده: 0 دانشگاه های خارج از کشور

background: inclusion of inhomogeneity corrections in intensity modulated small fields always makes conformal irradiation of lung tumor very complicated in accurate dose delivery. objective: in the present study, the performance of five algorithms via monte carlo, pencil beam, convolution, fast superposition and superposition were evaluated in lung cancer intensity modulated radiotherapy planni...

Journal: :علوم و تکنولوژی پلیمر 0
محمد نجفی حسین روغنی ممقانی مهدی سلامی کلجاهی وحید حدادی اصل

atom transfer radical polymerization (atrp) of styrene was carried out at 105°c and a monte carlo simulation was employed to model the system. the variations of monomer conversion, the initiator concentration, average molecular weight, and molecular weight distribution were evaluated as the reaction proceeded. according to the results obtained, for similar reaction time, monomer conversion is h...

M. Allahverdi, M.H. Zahmatkesh, M.R. Ay, N. Riyahi Alam, T. Allahverdi Pourfallah,

Background: Polymer gel dosimetry is still the only dosimetry method for direct measuring of threedimensional dose distributions. MRI Polymer gel dosimeters are tissue equivalent and can act as a phantom material. In this study the obtained isodose maps with PAGAT polymer gel dosimeter were compared to those calculated with EGSnrs for singleshot irradiations of 8 and 18 mm collimators of...

Journal: :iranian journal of radiation research 0
t. allahverdi pourfallah department of medical physics and biomedical engineering, tehran university of medical sciences, tehran, iran m. allahverdi department of medical physics and biomedical engineering, tehran university of medical sciences, tehran, iran n. riyahi alam department of medical physics and biomedical engineering, tehran university of medical sciences, tehran, iran m.r. ay research center for science and technology in medicine, tehran university of medical sciences, tehran, iran m.h. zahmatkesh novin medical radiation institute, tehran, iran

background: polymer gel dosimetry is still the only dosimetry method for direct measuring of threedimensional dose distributions. mri polymer gel dosimeters are tissue equivalent and can act as a phantom material. in this study the obtained isodose maps with pagat polymer gel dosimeter were compared to those calculated with egsnrs for singleshot irradiations of 8 and 18 mm collimators of gamma ...

Journal: :journal of biomedical physics and engineering 0
m. mahdavi ph.d, physics depart- ment, mazandaran uni- versity, babolsar, iran m. khadem-abolfazli m.sc, para medical de- partment, babol univer- sity of medical sciences, babol, iran s. r. m. mahdavi ph.d, medical physics department, tehran university of medical sci- ences, tehran, iran gh. ataei m.sc, para medical de- partment, babol univer- sity of medical sciences, babol, iran

background: radiation-sensitive polymer gels are among the most promising three-dimensional dose verification tools and tissue-like phantom developed to date. objective: the aim of this study is an investigating of percentage depth dose enhancement within the gel medium with used of conformal distribution gold nanoparticle as contrast agents by high atomic number material. methods: in this work...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید