نتایج جستجو برای: mri dosimetry

تعداد نتایج: 113785  

Fatemeh Sadat Ghoreshi Issac Shiri Jaber Beik Keikhosro Keshavarzi Seyed Rabee Mahdi Mahdavi

Introduction: Currently, the potential application of gold nanoparticles (AuNPs) to increase the efficiency of radiation therapy have been investigated. However, the loss of an appropriate method to estimate the dose distribution in nanoparticle laden tissue limits the applicability of nanoparticles in radiotherapy clinics. Polymer gel dosimetry provides an accurate and precise...

M. Allahverdi, M.H. Zahmatkesh, M.R. Ay, N. Riyahi Alam, T. Allahverdi Pourfallah,

Background: Polymer gel dosimetry is still the only dosimetry method for direct measuring of threedimensional dose distributions. MRI Polymer gel dosimeters are tissue equivalent and can act as a phantom material. In this study the obtained isodose maps with PAGAT polymer gel dosimeter were compared to those calculated with EGSnrs for singleshot irradiations of 8 and 18 mm collimators of...

Ghorban Safaeian, Mina Nouri, Mohammad Hosein Bahreyni Toossi Mohammad Taghi Bahreyni Toossi Shahram Bayani

Introduction: The objective of this work is to study the ability of MRI normoxic polymer gel dosimetry system to be used to verify the calculated dose distribution, in a simple geometry, in clinical radiotherapy. Materials and Methods:  Initially, 2 liters of the normoxic MAGAT polymer gel was prepared and then poured into two cylindrical Perspex phantom (simu...

Abbas Takavar, Behrooz Rafiee Ehsan Mohammadi Kavous Firoznia Morteza Bakhtiary Nader Riyahi-Alam Peiman Hadad Reza Moghadam-Drodkhani Zohre Tizmaghz

Introduction: The conventional methods of dosimetry are not capable of dosimetry in such a small volume of less than one cubic millimeter. Although the polymer gel dosimetry method based on magnetic resonance imaging (MRI) could achieve three dimensional dosimetry with high resolution, a spatial resolution evaluation based on gel dose modulation transfer function has not been investigated yet. ...

Journal: :Journal of Physics: Conference Series 2009

2014
Austin N. Kirschner Vythialingam Sathiaseelan Yunkai Zhang James David John A. Kalapurakal

PURPOSE While there are several reports of prostate multisector dosimetry data obtained from CT or MRI scans performed at intervals ranging from 14-70 days after prostate brachytherapy (PB), there are no reports on multisector dosimetry performed in the immediate post-implant period. This study was undertaken to determine the results of prostate multisector dosimetry performed in the immediate ...

2016
Silvia Rodríguez Villalba Jose Richart Sancho Antonio Otal Palacín Jose Perez-Calatayud Manuel Santos Ortega

PURPOSE To study outcome and toxicity in 59 patients with locally advanced cervix carcinoma treated with computed tomography (CT)-based Martinez universal perineal interstitial template (MUPIT) and the new magnetic resonance imaging (MRI)-compatible template Benidorm (TB). MATERIAL AND METHODS From December 2005 to October 2015, we retrospectively analyzed 34 patients treated with MUPIT and 2...

Journal: :iranian journal of radiation research 0
t. allahverdi pourfallah department of medical physics and biomedical engineering, tehran university of medical sciences, tehran, iran m. allahverdi department of medical physics and biomedical engineering, tehran university of medical sciences, tehran, iran n. riyahi alam department of medical physics and biomedical engineering, tehran university of medical sciences, tehran, iran m.r. ay research center for science and technology in medicine, tehran university of medical sciences, tehran, iran m.h. zahmatkesh novin medical radiation institute, tehran, iran

background: polymer gel dosimetry is still the only dosimetry method for direct measuring of threedimensional dose distributions. mri polymer gel dosimeters are tissue equivalent and can act as a phantom material. in this study the obtained isodose maps with pagat polymer gel dosimeter were compared to those calculated with egsnrs for singleshot irradiations of 8 and 18 mm collimators of gamma ...

Journal: :iranian journal of medical physics 0
reza moghadam-drodkhani m.sc. in medical physics, medical physics and engineering dept., faculty of medicine, tehran university of medical sciences, tehran, iran nader riyahi-alam professor, medical physics and engineering dept., faculty of medicine, tehran university of medical sciences, tehran, iran abbas takavar professor, medical physics and engineering dept., faculty of medicine, tehran university of medical sciences, tehran, iran kavous firoznia associate professor, radiology dept., imaging center of imam khomeini hospital, faculty of medicine, tehran university of medical sciences, tehran, iran peiman hadad associate professor, radiotherapy dept., imam khomeini hospital, faculty of medicine, tehran university of medical sciences, tehran, iran behrooz rafiee m.sc., radiology dept., imaging center of imam khomeini hospital, faculty of medicine, tehran university of medical sciences, tehran, iran

introduction: the conventional methods of dosimetry are not capable of dosimetry in such a small volume of less than one cubic millimeter. although the polymer gel dosimetry method based on magnetic resonance imaging (mri) could achieve three dimensional dosimetry with high resolution, a spatial resolution evaluation based on gel dose modulation transfer function has not been investigated yet. ...

2017
S Mein L Rankine D Miles T Juang B Cai M Oldham

To develop and apply a remote dosimetry protocol with PRESAGE® radiochromic plastic and optical-CT readout in the validation of MRI guided radiation therapy (MRgRT) treatments (MRIdian® by ViewRay®). Through multi-institutional collaboration we performed PRESAGE® dosimetry studies in 4ml cuvettes to investigate dose-response linearity, MRcompatibility, and energy-independence. An open calibrati...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید