نتایج جستجو برای: nerve conduit

تعداد نتایج: 170300  

2017
Mehmet S. Arda Emre A. Koçman Emre Özkara Erdem Söztutar Orhan Özatik Aydan Köse Cengiz Çetin

BACKGROUND Autologous nerve grafts are used to bridge peripheral nerve defects. Limited sources and donor site morbidity are the major problems with peripheral nerve grafts. Although various types of autologous grafts such as arteries, veins and muscles have been recommended, an ideal conduit has not yet been described. AIMS To investigate the effectiveness of a small intestinal conduit for p...

Journal: :Advances in clinical and experimental medicine : official organ Wroclaw Medical University 2014
Ahmad Fadzli Sulong Nur Hidayah Hassan Ng Min Hwei Yogeswaran Lokanathan Amaramalar Selvi Naicker Shalimar Abdullah Mohd Reusmaazran Yusof Ohnmar Htwe Ruszymah Bt Hj Idrus Nor Hazla Mohamed Haflah

BACKGROUND Autologous nerve grafts to bridge nerve gaps pose various drawbacks. Nerve tissue engineering to promote nerve regeneration using artificial neural conduits has emerged as a promising alternative. OBJECTIVES To develop an artificial nerve conduit using collagen-coated polylactic-glycolic acid (PLGA) and to analyse the survivability and propagating ability of the neuro-differentiate...

Journal: :Journal of neural engineering 2013
A F Quigley K J Bulluss I L B Kyratzis K Gilmore T Mysore K S U Schirmer E L Kennedy M O'Shea Y B Truong S L Edwards G Peeters P Herwig J M Razal T E Campbell K N Lowes M J Higgins S E Moulton M A Murphy M J Cook G M Clark G G Wallace R M I Kapsa

Injury to nerve tissue in the peripheral nervous system (PNS) results in long-term impairment of limb function, dysaesthesia and pain, often with associated psychological effects. Whilst minor injuries can be left to regenerate without intervention and short gaps up to 2 cm can be sutured, larger or more severe injuries commonly require autogenous nerve grafts harvested from elsewhere in the bo...

2016
Basak Acan Clements Jared Bushman N Sanjeeva Murthy Mindy Ezra Christopher M Pastore Joachim Kohn

Here, we report on the design of braided peripheral nerve conduits with barrier coatings. Braiding of extruded polymer fibers generates nerve conduits with excellent mechanical properties, high flexibility, and significant kink-resistance. However, braiding also results in variable levels of porosity in the conduit wall, which can lead to the infiltration of fibrous tissue into the interior of ...

Endoscopic radial artery harvesting (ERAH) is a feasible and attractive minimally invasive approach for conduit procurement, however there have been concerns about a potential neurological damage occurring at the harvest limb site secondary to injury of the radial nerve during endoscopic harvesting. We present a case of ERAH in which we evaluated intraoperatively the characteristics of radial n...

2015
Kamal Seyed Foroutan Ali Khodarahmi Hootan Alavi Sepehr Pedram Mohamad Reza Baghaban Eslaminejad Sima Bordbar

BACKGROUND Peripheral nerve repair with sufficient functional recovery is an important issue in reconstructive surgery. Stem cells have attracted extensive research interest in recent years. OBJECTIVES The purpose of this study was to compare the vein conduit technique, with and without the addition of mesenchymal stem cells in gap-less nerve injury repair in rats. MATERIALS AND METHODS In ...

2013
Peixun Zhang Na Han Tianbing Wang Feng Xue Yuhui Kou Yanhua Wang Xiaofeng Yin Laijin Lu Guanglei Tian Xu Gong Shanlin Chen Yu Dang Jianping Peng Baoguo Jiang

Nerve regeneration and re-innervation are usually difficult after peripheral nerve injury. Epineurium neurorrhaphy to recover the nerve continuity is the traditional choice of peripheral nerve mutilation without nerve defects, whereas the functional recovery remains quite unsatisfactory. Based on previous research in SD rats and Rhesus Monkeys, a multiple centers clinical trial about biodegrada...

Journal: :veterinary research forum 2012
saeed azizi rahim mohammadi keyvan amini roza fallah kiana karegar

despite promising results observed using silicone rubber chamber, no previous comprehensive work was performed on behavior of the conduit. present study aimed at further functional, histomorphometrical and immunohistochemical assessment of nerve regeneration in the same animal along a 10-mm rat sciatic nerve gap. fifty- four male wistar rats were divided into three experimental groups (n = 18),...

2017
Jie Tao Yu Hu Shujuan Wang Jiumeng Zhang Xuan Liu Zhiyuan Gou Hao Cheng Qianqi Liu Qianqian Zhang Shenglan You Maling Gou

End-to-end neurorrhaphy is the most commonly used method for treating peripheral nerve injury. However, only 50% of patients can regain useful function after treating with neurorrhaphy. Here, we constructed a 3D-engineered porous conduit to promote the function recovery of the transected peripheral nerve after neurorrhaphy. The conduit that consisted of a gelatin cryogel was prepared by molding...

Objective- To studylocal effect of prostaglandin E1on sciatic nerve regeneration Design- Experimental study Animals- Sixty male healthy white Wistar rats Procedures- Sixty animals were divided into four experimental groups (n = 15), randomly: Trasnsected (TC), Sham-operation (SHAM), control (CHIT) and prostagl...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید