Journal: :Medical physics 1997
W R Geiser W Huda N A Gkanatsios

An investigation was performed of the changes in image quality and patient dose as a result of increasing filtration for fluoroscopy performed under automatic brightness control. Filtration was added either at the x-ray tube housing (i.e., scatter-free geometry) or adjacent to a tissue equivalent phantom simulating the patient (i.e., with-scatter geometry). Patient doses were expressed in terms...

Journal: :Journal of nuclear medicine technology 2003
Douglass C Vines Masanori Ichise Jeih-San Liow Hiroshi Toyama Robert B Innis

OBJECTIVE Scatter correction is an important factor in quantitative SPECT. In this study, we evaluated 2 methods of scatter correction for brain SPECT. The first is based on thresholding the energy spectrum (ES), and the second is based on a modification of the transmission-dependent convolution subtraction (TDCS) method. METHODS SPECT imaging of a skull striatal phantom was performed using a...

Journal: :Kaku igaku. The Japanese journal of nuclear medicine 2007
Akihiro Takaki Satomi Teraoka Tsutomu Soma Tomonori Murakami Akihiro Kojima Masanori Matsumoto Kenya Murase

In order to perform experimental measurements for evaluation of imaging device's performance, data acquisition technique, and clinical images on scintigraphic imaging, many kinds of phantoms are employed. However, since these materials are acrylic and plastic, the thickness and quality of those materials cause attenuation and scatter in itself. We developed a paper sheet phantom sealed with a p...

2005
P. Ghaffarian A. A. Sharafi K. Keshavarz H. Zaidi

The MCNP Monte Carlo radiation transport code was used for calculation of scatter distribution and scatter-toprimary ratio (SPR) for different tube voltages, phantom thicknesses and field size in diagnostic radiology. Subsequently, the effect of grid’s design parameters such as strip density, grid ratio, interspace material and lead-tointerspace ratio on scatter rejection was investigated by ca...

Journal: :Medical physics 2006
Geneviève Jarry Sean A Graham Douglas J Moseley David J Jaffray Jeffrey H Siewerdsen Frank Verhaegen

Kilovoltage (kV) cone beam computed tomography (CBCT) images suffer from a substantial scatter contribution. In this study, Monte Carlo (MC) simulations are used to evaluate the scattered radiation present in projection images. These predicted scatter distributions are also used as a scatter correction technique. Images were acquired using a kV CBCT bench top system. The EGSnrc MC code was used...

F. Haryanto, I. Arif, M.F. Rhani, R.C.X. Soh, S. Yani,

Background: The lack of lateral electronic disequilibrium (LED) becomes a main problem in small field. This factor affects the dose in target volume cannot predict correctly. In addition, utilization of high-energy linear accelerator (10 MV) can emit some unwanted particles (electron contamination). Therefore, the aim of this study was to characterize head linear accelerator (linac) Varian Clin...

Journal: :iranian journal of radiation research 0
m.r. teimoori sichani department of medical radiation engineering, science and research branch, islamic azad university, tehran, iran m. amoui department of nuclear medicine, shahid beheshti university of medical science, tehran, iran sh. akhlaghpoor noor medical imaging center, tehran, iran m. hosntalab department of medical radiation engineering, science and research branch, islamic azad university, tehran, iran

background: in this study, quantitative 32p bremsstrahlung planar and spect imaging and consequent dose assessment were carried out as a comprehensive phantom study to define an appropriate method for accurate dosimetry in clinical practice. materials and methods: ct, planar and spect bremsstrahlung images of jaszczak phantom containing a known activity of 32p were acquired. in addition, phanto...

2015
Peter G.F. Watson Ernesto Mainegra‐Hing Nada Tomic Jan Seuntjens

Cone-beam computed tomography (CBCT) images suffer from poor image quality, in a large part due to contamination from scattered X-rays. In this work, a Monte Carlo (MC)-based iterative scatter correction algorithm was implemented on measured phantom data acquired from a clinical on-board CBCT scanner. An efficient EGSnrc user code (egs_cbct) was used to transport photons through an uncorrected ...

2010
A Akbarzadeh MR Ay H Ghadiri S Sarkar H Zaidi

PURPOSE The consummate 64-slice CT scanner that spawns a new generation of non-invasive diagnostic tool, however revolutionary, brings with it the incidental by-product that is scattered radiation. The extended detector aperture capability in the 64-slcie CT scanner allows the effects of scattered radiation to be more pronounced and therefore demands that the magnitude and spatial distribution ...