نتایج جستجو برای: photon attenuation coefficient
تعداد نتایج: 284445 فیلتر نتایج به سال:
background: in radiation therapy, the sparing of normal tissues can be performed using either multi-leaf collimators or cerrobend blocks. the current work focuses on the physical characteristics of cerrobend blocks including attenuation coefficient, effective penumbra width and isodose curves undulation in penumbral regions. materials and methods: all measurements were performed using a dual en...
The probability of a photon (x-ray, gamma-ray, bremsstrahlung, etc) of a given energy E undergoing absorption or scattering when traversing a layer of material Z can be expressed quantitatively in terms of a linear attenuation coefficient mu (cm(-1)). Since mu is dependent on the material's density, rho (g cm(-3)), which can be variable, the quantity usually tabulated is the mass attenuation co...
Mass attenuation coefficients and partial photon interactions have been calculated theoretically at incident photon energy 1 Kev to 100 GeV for garnet series of gemstones (Grosaularite (GS1), Pyrope(GS2), Spessarlite(GS3), Almandine(GS4), Uvarovite(GS5) and Androdite(GS6) using XCOM software [1]. The values of these parameters have been found to change significantly with incident photon energy ...
osting by E Abstract The variation of photon attenuation coefficient on the chemical media has been investigated. For this purposes the linear attenuations of barite concrete have been measured at 662, 1773 and 1332 keV before leaving the chemical media and following a 6 month period. The linear attenuation coefficients have been measured using gamma spectrometer that contains a NaI(Tl) detecto...
Purpose: Fiber carbon is the most common material used in treating couch as it causes less beam attenuation than other materials. Beam attenuation replaces build-up region, reduces skin-sparing effect and causes target volume under dosage. In this study, we aimed to evaluate beam attenuation and variation of build-up region in 550 TxT radiotherapy couch.Materials and Methods: In this study, we ...
Background: In Radiation Therapy, the sparing of normal tissues can be performed using either multi-leaf collimators or Cerrobend blocks. The current work focuses on the physical characteristics of Cerrobend blocks including attenuation coefficient, effective penumbra width and isodose curves undulation in penumbral regions. Materials and Methods: All measurements were performed using ...
The characterization of the incident photon beam is usually divided into its dependence on collimator setting (head-scatter factor) and off-axis position (primary off-axis ratio). These parameters are normally measured "in air" with a build-up cap thick enough to generate full dose build-up at the depth of dose maximum. In order to prevent any influence from contaminating electrons, it has been...
Background: Radiation shielding properties is an important for a material wish can be used the photon attenuation coefficients of clay produced using different rate of boron have been measured for the purpose of radioactive waste disposal. Materials and Methods: The measurement has been performed using gamma spectrometer contains NaI (Tl) detector at the photon energies of 662, 1173 an...
Introduction: The main goal of SPECT imaging is to determine activity distribution inside the organs of the body. However, due to photon attenuation, it is almost impossible to do a quantitative study. In this paper, we suggest a mathematical relationship between activity distribution and its corresponding projections using a transfer matrix. Monte Carlo simulation was used to find a precise tr...
objective: in this study, we aimed to validate the accuracy of computed tomography-based attenuation correction (ctac) using the bilinear scaling method.methods: the measured attenuation coefficient (μm) was compared to a theoretical attenuation coefficient (μt ) using four different ct scanners and an rmi 467 phantom. the effective energy of the ct beam x-rays was calculated, using the aluminu...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید