نتایج جستجو برای: polymer gel treatment

تعداد نتایج: 1570732  

میرجلیلی, غضنفر, برهانی زرندی, محمود , بلوری زاده, محمد آقا , ضیائی, فرهود,

Samples from two type of polyethylene, with low and high density, had been subjected to three different initial processing. The samples were heated to 170 oC and then cooled by different cooling rating in air, in mold (10 oC/min cooling rate) and in 0.0 oC water. Following this step, each sample irradiated by 10 MeV electron beam. The gel content of the samples, which is a measure of interchain...

Journal: :iranian journal of chemistry and chemical engineering (ijcce) 2007
mohammad simjoo mohsen vafaie sefti ahmad dadvand koohi reza hasheminasab valiahmad sajadian

in this paper, polyacrylamide/chromium acetate gel polymer system was prepared as water shut-off system to control water production in one of the iranian oil reservoirs condition. effect of various parameters such as temperature (90 °c) and water formation from view point of salinity and divalent cations, was evaluated on the gelation kinetic and gel strength using bottle testing method. the re...

Journal: :iranian journal of radiation research 0
w. parwaie department of radiology, faculty of para-medicine, hormozgan university of medical sciences, bandar abbas, iran m. yarahmadi department of medical physics, faculty of medicine, kurdistan university of medical sciences, sanandaj, iran h.a. nedaie department of radiotherapy, cancer institute, tehran university of medical sciences, tehran, iran m.h. zahmatkesh shahid beheshti university of medical sciences, tehran, iran a.h. barati department of medical physics, faculty of medicine, kurdistan university of medical sciences, sanandaj, iran m. afkhami department of radiology, faculty of para-medicine, hormozgan university of medical sciences, bandar abbas, iran

background: accurate small radiation field dosimetry is essential in modern radiotherapy techniques such as stereotactic radiosurgery (srs) and intensity modulated radiotherapy (imrt). precise measurement of dosimetric parameters such as beam profile, percentage depth doses and output factor of these beams are complicated due to the electron disequilibrium and the steep dose gradients. in the p...

Journal: :iranian journal of medical physics 0
hamid reza sadoughi m.sc. student of medical physics, medical physics dept., tehran university of medical sciences, tehran, iran mahmood allahverdi associate professor, medical physics dept., tehran university of medical sciences, and radiotherapy physics department of cancer institute, tehran, iran hasan nedaei assistant professor, radiotherapy physics dept., cancer institute, tehran, iran ramin jaberi radiotherapy physicist, radiotherapy physics dept., cancer institute, tehran, iran mahbod esfahani radiotherapy physicist, radiotherapy physics dept., cancer institute, tehran, iran alireza shirazi associated professor, medical physics dept., tehran university of medical sciences, tehran, iran

introduction: multiple fields and presence of heterogeneities create complex dose distributions that need three dimensional dosimetry. in this work, we investigated mr-based magic gel dosimetry as a three-dimensional dosimetry technique to measure the delivered dose to bladder and rectum in prostate radiation therapy. materials and methods: a heterogeneous slab phantom including bones was made....

Journal: :iranian journal of radiation research 0
b. azadbakht department of nuclear engineering, shiraz university, shiraz, iran m.h. zahmatkesh novin medical research institute, tehran, iran k. hadad department of nuclear engineering, shiraz university, shiraz, iran s. bagheri novin medical research institute, tehran, iran

background: in this work investigation of the normoxic pagat polymer gel dosimeter such as sensitivity, the r2-dose response with post time and the percentage depth dose (pdd) of pagat polymer gel dosimeter have been undertaken. materials and methods: using mri, the formulation to give the maximum change in the transverse relaxation rate r2 was determined to be 4.5% n,n'-methylenbis- acryl...

A. Takavar, A. Vaezzadeh, H.A. Nedaie, M. Keshtkar, M. Naderi, M.H. Zahmatkesh,

Background: Some tissues in human body are radiobiologically different from water and these inhomogeneity must be considered in dose calculation in order to achieve an accurate dose delivery. Dose verification in complex radiation therapy techniques, such as intensity‐modulated radiation therapy (IMRT) calls for volumetric, tissue equivalent and energy independent dosimeter. The purpose of this...

2014
Yves De Deene Andrew Jirasek

Three-dimensional (3D) gel dosimetry has a unique role to play in safeguarding conformal radiotherapy treatments as the technique can cover the full treatment chain and provides the radiation oncologist with the integrated dose distribution in 3D. It can also be applied to benchmark new treatment strategies such as image guided and tracking radiotherapy techniques. A major obstacle that has hin...

Journal: :iranian journal of medical physics 0
reza moghadam-drodkhani m.sc. in medical physics, medical physics and engineering dept., faculty of medicine, tehran university of medical sciences, tehran, iran nader riyahi-alam professor, medical physics and engineering dept., faculty of medicine, tehran university of medical sciences, tehran, iran abbas takavar professor, medical physics and engineering dept., faculty of medicine, tehran university of medical sciences, tehran, iran kavous firoznia associate professor, radiology dept., imaging center of imam khomeini hospital, faculty of medicine, tehran university of medical sciences, tehran, iran peiman hadad associate professor, radiotherapy dept., imam khomeini hospital, faculty of medicine, tehran university of medical sciences, tehran, iran behrooz rafiee m.sc., radiology dept., imaging center of imam khomeini hospital, faculty of medicine, tehran university of medical sciences, tehran, iran

introduction: the conventional methods of dosimetry are not capable of dosimetry in such a small volume of less than one cubic millimeter. although the polymer gel dosimetry method based on magnetic resonance imaging (mri) could achieve three dimensional dosimetry with high resolution, a spatial resolution evaluation based on gel dose modulation transfer function has not been investigated yet. ...

K. Adinehvand, M.H. Zahmatkesh, M.R Aghamiri, S. Bagheri, Sh. Akhlaghpour,

Background: The purpose of this study was to evaluate the dependency of MAGICA polymer gel dosimeter response (R2) on different electron energies as well as on different mean dose rate for a standard clinically used linear accelerator. Materials and Methods: The sensitivity of the dosimeter was represented by the slope of calibration curve in the linear region measured for each modalit...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید