نتایج جستجو برای: potentiometric determination

تعداد نتایج: 253339  

E. Baghdar M. Darvishpour M.H. Fekri

A poly(vinyl chloride) membrane based on a new a-dioxime derivative as membrane carrier was prepared andinvestigated as a Cr(III) selective electrode. The electrode exhibits a good potentiometric response for Cr(III)over a wide concentration range 1.0 x 10-6 to 1.0 x 10-1 M with a slope 19.5+0.5 mV/decade and low detectionlimit of 8.9 x 10-7 M. It has a fast response time < 15 s. The best perfo...

Journal: :The Journal of General Physiology 1948
John H. Northrop

A convenient reference cell and method of potentiometric determination of chloride ions with silver nitrate is described. The method is accurate to about +/- 0.02 ml. 10(-4)M silver nitrate.

Journal: :Scientific Bulletin of the Uzhhorod University. Series «Chemistry» 2019

2013
FIZ F. PEREZ

Perez, F.F. and Fraga, F., 1987. A precise and rapid analytical procedure for alkalinity determination. Mar. Chem., 21: 169-182. A potentiometric analytical method is proposed for the determination of the alkalinity of seawater. The precision is 0.1% and each determination takes 3 min. The technique is very easy to use, even on board ship since it is carried out in open flasks. A polynomial equ...

Journal: :Open Access Journal of Toxicology 2018

Journal: :Analytical sciences : the international journal of the Japan Society for Analytical Chemistry 2006
María Jesús Gismera María Teresa Sevilla Jesús R Procopio

Dithiodibenzoic (DTB) acid and mercaptobenzoic (MB) acid were studied to characterize their abilities as modifier agents for lead(II) sensors. For both sensors, the best results were obtained with modified carbon paste electrodes with 24.1% of ligand. The pH influence on the potentiometric response was studied. The selectivity coefficients for both modified electrodes were tabulated. A potentio...

2014
VANIA MASLARSKA

A direct potentiometric titration method was applied for determination of Ranitidine Hydrochloride. The method is based on the treatment of the primary data with nonlinear regression procedure using commercial software. A general formula valid for every type of acid base titration, derived before is used as a direct input. The acid-base constants of N, N dimethyl-5 [2-(1-methylamine-2-nitroviny...

2008
R. V. P. Leal P. P. Borges P. R. Seidl

Based on international standard procedures, the degree of unsaturation on biodiesel was evaluated, called iodine value. Two titration techniques were used to determine the iodine value: colorimetric and potentiometric techniques. The uncertainty of measurement was used to evaluate the quality of the results. The potentiometric technique showed better quality in the determination of the iodine v...

نمودار تعداد نتایج جستجو در هر سال