نتایج جستجو برای: potentiometric sensor
تعداد نتایج: 191184 فیلتر نتایج به سال:
A new polyvinyl choloride (PVC) membrane sensor for cerium (III) was prepared based on 4,13-didecyl-1,7,10,16-tetraoxa-4,13-diazacyclooctadecane (kryptofix22DD) as an ionophore. The sensor exhibites a linear concentration range of 1.0×10-6 to 1.0×10-1 M, with a Nernstian slope of 18.0±1.0 mV/decade, and a detection limit of 9.7×10-7 M. It has a fast response time (5 s) and can be used for two m...
"Green analytical chemistry" (GAC) succeeded to become an eco-friendly environmental crucial area in the field of analytical chemistry targeting at the chemical processes' and products' optimization regarding to material consumption, generation of waste and intrinsic safety, toxicity and environmental burdens. For an expressive comparison, an electro-analytical in-line potentiometric selective ...
An enzyme-metal-insulator-silicon (EMIS) structured chemical sensor based on photovoltage technology is constructed for potentiometric biosensing of glucose in a flow-injection analysis (FIA) system. To enhance the sensibility of the sensor to glucose, an ultra-thin (60 nm) film of polypyrrole (PPy)-glucose oxidase (GOD) is formed as the glucose-sensitive membrane through a simple electropolyme...
The construction and general performance of thirteen new polymeric membrane sensors for the determination of fexofenadine hydrochloride based on its ion exchange with reineckate, tetraphenylborate and tetraiodomercurate have been studied. The effects of membrane composition, type of plasticizer, pH value of sample solution and concentration of the analyte in the sensor internal solution have be...
a carbon-past electrode modified with iron(ii) phathalocyanine (fepc) was used as a sensitive potentiometric sensor for determination of 2-pyridinethiol (2pt). 2-mercaptoethanol (2me) and sulfide ion in aqueous solutions. the modified electrode acts as an electrocatalyst for oxidation of these compounds, and lowers the overpotential for oxidation reactions by more than 400 mv, compared to the u...
a new polyvinyl choloride (pvc) membrane sensor for cerium (iii) was prepared based on 4,13-didecyl-1,7,10,16-tetraoxa-4,13-diazacyclooctadecane (kryptofix22dd) as an ionophore. the sensor exhibites a linear concentration range of 1.0×10-6to 1.0×10-1m, with a nernstian slope of 18.0±1.0 mv/decade, and a detection limit of 9.7×10-7m. it has a fast response time (5 s) and can be used for two mont...
An improved protamine-sensitive electrode based on a polymeric membrane doped with the charged ion exchanger dinonylnaphthalenesulfonate (DNNS) is used for monitoring heparin concentrations in whole blood. The electrode exhibits significant nonequilibrium potentiometric response to polycationic protamine over the concentration range of 0.5-20 mg/L in undiluted whole-blood samples. The sensor ca...
A potentiometric non-enzymatic sensor using off-chip extended-gate field effect transistor (EGFET) with a ferrocenyl-alkanethiol modified gold electrode is demonstrated for determining the uric acid concentration in human serum and urine. Hexacyanoferrate (II) and (III) ions are used as redox reagent. This potentiometric sensor measures the interface potential on the ferrocene immobilized gold ...