نتایج جستجو برای: potentiometry ion selective membrane electrode

تعداد نتایج: 802881  

Journal: :journal of physical & theoretical chemistry 2012
m. h. fekri m. darvishpour

a pvc membrane ni(ii) ion selective electrode has been constructed using (1e,2e)-bis(2-aminophenyl)n'1,n'2-dihydroxyethanebis as membrane carrier. the electrode exhibited a goodpotentiometric response for ni(ii) over a wide concentration range 1.0×10-4 to 1.0×10-1m with aslope of 29.4±0.5 mv/decade a and a working ph range of 6.5-9.0. it had a fast response time of≤20s. the best performance was...

Journal: :journal of physical & theoretical chemistry 2012
r. aminameli m. h. fekri h. shafie m. darvishpour h. khanmohammadi

a pvc membrane fe(iii) ion selective electrode has been constructed using a new macrocyclic asmembrane carrier.the electrode exhibits a good potentiometric response for fe(iii) over a wideconcentration range 1.0×10-4 to 1.0×10-1m with a slope 19.4±0.5 mv/decade a and a working phrange of 6.5-9.0. it has a fast response time ≤30s.the best performance was observed with themembrance having the 30....

Journal: :journal of physical and theoretical chemistry 0
m. h. fekri - m. darvishpour -

a pvc membrane ni(ii) ion selective electrode has been constructed using (1e,2e)-bis(2-aminophenyl)n'1,n'2-dihydroxyethanebis as membrane carrier. the electrode exhibited a goodpotentiometric response for ni(ii) over a wide concentration range 1.0×10-4 to 1.0×10-1m with aslope of 29.4±0.5 mv/decade a and a working ph range of 6.5-9.0. it had a fast response time of≤20s. the best perfo...

Journal: :Analytical chemistry 2008
Yushin Kim Shigeru Amemiya

A highly sensitive analytical method is required for the assessment of nanomolar perchlorate contamination in drinking water as an emerging environmental problem. We developed the novel approach based on a voltammetric ion-selective electrode to enable the electrochemical detection of "redox-inactive" perchlorate at a nanomolar level without its electrolysis. The perchlorate-selective electrode...

Journal: :Acta chimica Slovenica 2011
Mojtaba Shamsipur Shokat Sahari Mahmood Payehghadr Kamal Alizadeh

1, 3-Bis(2-cyanobenzene)triazene, L, was used as a suitable ionophore for the fabrication of a new PVC-based polymeric membrane coated graphite electrode for selective sensing of Cd2+ ion. The electrode exhibited a selective linear Nernstian response to Cd2+ ion at an optimal pH range of 6-9 with a limit of detection of 8.0 × 10-6 M and a fast response time of about 2 s. The electrode was used ...

Journal: :physical chemistry and electrochemistry 0

a pvc ion-selective membrane electrode based on cd-tetraphenyl porphyrine as a carrier was prepared fordetermination of mno4- ion. this electrode revealed good selectivity toward permanganate ion over a widevariety of anions. effects of some experimental parameters such as nature of the plasticizer, the amounts ofcarrier and additive, and concentration of the internal solution on the potential ...

2012
Farnoush Faridbod

Clomipramine hydrochloride, active component of an antidepressant drug, was determined in the pharmaceutical formulation by two kinds of potentiometric sensor; a PVC membrane sensor and a carbon paste electrode modified by MWCNTs and ionic liquid. Both sensors were corporated with clomipramine-tetraphenylborate ion-pair complex and they respond based on ion exchange mechanism. The best PVC memb...

Journal: :Angewandte Chemie 2007
Eric Bakker Ernö Pretsch

For most chemists, potentiometry with ion-selective electrodes (ISEs) primarily means pH measurements with a glass electrode. Those interested in clinical analysis might know that ISEs, routinely used for the determination of blood electrolytes, have a market size comparable to that of glass electrodes. It is even less well known that potentiometry went through a silent revolution during the pa...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید