نتایج جستجو برای: pulse height distributions
تعداد نتایج: 320960 فیلتر نتایج به سال:
An algorithm for the derivation of LET-distributions from pulse-height spectra obtained with proportional counters is described. The method is based on Fourier transformation; it is applicable to spherical as well as non-spherical proportional counters. The relation between the energy mean, E,, of LET and the energy mean, g , , of the lineal energy density is given. 1. Introduction Tissue equiv...
Latest results from radiation hardness measurements as well as single-particle pulse shape parameters, pulse-height distributions and time spectra are presented. An intrinsic time resolution of 29 ps is achieved with 52Cr ions of 650 MeV/amu and of 53 ps with 12C ions of 1.5 GeV/amu, respectively. The resolution is by 20% worse when increasing the beam intensity from 106 ions/s to 108 ions/s. P...
Harvey, R. J. (University of California, Davis), and Allen G. Marr. Measurement of size distributions of bacterial cells. J. Bacteriol. 92:805-811. 1966.-Apparatus for the automatic determination of the volume distribution of particles by measurement of the amplitude of pulses generated in a Coulter transducer is described. Distributions of volume estimated by direct measurement of pulse amplit...
In organic scintillators, the energy distribution of gamma rays and neutrons is indirectly measured by the pulse height distribution of light output produced through gamma ray and neutron reactions in the detectors. Accurate estimate of the interaction of gamma and neutrons in the detector and produce charged secondary particles and subsequent scintillation light produced in the calculation of ...
In order to Study the quality of diameter at breast height distribution, height and height till the beginning of the crown of Oak trees in un-even aged stands from the collected data of the forestation plan in Shanderman Siyahkesh Guilan province, 367 trees were randomly selected as samples and the diameter, height and the height till the beginning of the crown were analyzed. According to the...
Regression models for above-ground and below-ground biomass were estimated for 143 sample plots in young and mature coniferous forest. Various canopy height and canopy density metrics derived from the canopy height distributions of first as well as last pulse laser scanner data with a sampling density of approximately 1.1 m were used as independent variables in the regressions. Each of the sele...
The multichannel analyzer (MCA) is an important laboratory instrument which can measure distributions of input signals consisting of pulses. It operates in two different modes: pulse height analyzer (PHA) mode, and multichannel scaler (MCS) mode. In PHA mode, the input pulses are sorted into bins (channels) according to their amplitude, while in MCS mode they are sorted according to the time wh...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید