نتایج جستجو برای: pulse sequences

تعداد نتایج: 299737  

2010
Ileana Hancu Mark Frye John Port Ivan Dimitrov Deborah Douglas Jimin Ren Andrew G. Webb A Dean Sherry Craig R. Malloy Napapon Sailasuta Brian D. Ross Dinesh K. Deelchand Isabelle Iltis Pierre-Francois Van de Moortele Pierre-Gilles Henry

A theoretical study is performed to understand the accuracy and repeatability of multiple pulse sequences in quantifying glutamine concentration at 3T. Variable repeatability (12% to >50%) and significant bias (-30% to +70%) is noted for the seven pulse sequences considered. Data acquired in vivo using three of the pulse sequences used for simulations matches the predicted repeatability well. F...

Journal: :Journal of Cardiovascular Magnetic Resonance 2013

Journal: :Japanese Journal of Radiological Technology 1998

Journal: :NMR in biomedicine 2011
Ileana Hancu John Port

A theoretical study was performed to determine the accuracy and repeatability of multiple one-dimensional pulse sequences in the quantification of glutamine concentration at 3 T. Variable repeatability (12% to > 50%) and significant absolute error (-50% to +70%) were noted for the eight pulse sequences considered. Data acquired in vivo using three of the pulse sequences used for simulation matc...

Journal: :The Analyst 2016
Juan A Aguilar Simon J Kenwright

We describe the design and application of robust, general-purpose water signal suppression pulse sequences well suited to chemometric work. Such pulse sequences need to deal well with pulse mis-calibrations, radiation damping, chemical exchange, and the presence of sample inhomogeneities, as well as with significant variations in sample characteristics such as pH, ionic strength, relaxation cha...

F Faeghi H R Haghighatkhah J Abdolmohammadi Z Farshidfar,

Background and objective: Magnetic resonance imaging (MRI) is the most sensitive technique to detect multiple sclerosis (MS) plaques in central nervous system. In some cases, the patients who were suspected to MS, Whereas MRI images are normal, but whether patients don’t have MS plaques or MRI images are not enough optimized enough in order to show MS plaques? The aim of the current study is ...

Journal: :Journal of magnetic resonance 2008
B Kasumaj S Stoll

In 3-pulse ESEEM and the original 4-pulse HYSCORE, nuclei with large modulation depth (k approximately 1) suppress spectral peaks from nuclei with weak modulations (k approximately 0). This cross suppression can impede the detection of the latter nuclei, which are often the ones of interest. We show that two extended pulse sequences, 5-pulse ESEEM and 6-pulse HYSCORE, can be used as experimenta...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید