نتایج جستجو برای: removal torque

تعداد نتایج: 162806  

2015
Giselle Naback Lemes Vilani Antônio Carlos de Oliveira Ruellas Carlos Nelson Elias Cláudia Trindade Mattos

OBJECTIVE To compare in vivo orthodontic mini-implants (MI) of smooth (machined) and rough (acid etched) surfaces, assessing primary and secondary stability. METHODS Thirty-six (36) MI were inserted in the mandibles of six (6) dogs. Each animal received six (6) MI. In the right hemiarch, three (3) MI without surface treatment (smooth) were inserted, whereas in the left hemiarch, another three...

Journal: :The British journal of oral & maxillofacial surgery 2012
Bernd Stadlinger Stephen J Ferguson Uwe Eckelt Roland Mai Anna Theresa Lode Richard Loukota Falko Schlottig

Two groups of titanium dental implants, identical in geometry but different in the treatment of their surfaces, were tested in an in vivo minipig model of the mandible. The surfaces that were tested were, first, sandblasted and acid-etched; and secondly, sandblasted, acid-etched, and conditioned. The removal torque was assessed at 2, 4, and 8 weeks after implantation (n=6 animals in each healin...

2015
Jan Henrik Sörensen Lutz Dürselen Ken Welch Torben Christian Sörensen Philip Procter Håkan Engqvist Maria Strømme Anita Ignatius Hartwig Steckel

The early fixation of bone screws after surgical implantation still remains a challenge in the field of traumatology. Whilst hydroxyapatite (HA) coatings are known to enhance the fixation of implants; their removal at a later time-point may be problematic. An HA coating has been developed to demonstrate that both implant fixation and safe removal are feasible in the same design. Accordingly the...

2002
D. M. Devine L. P. Bouré J. Hahn A. Pearce E. Schneider R. Wieling R. G. Richards S. G. Pearce

Introduction: The success of an orthopaedic implant depends on several factors, such as implant material properties, design and fixation technique as well as bone apposition around the implant. Polyetheretherketone (PEEK) is a composite thermoplastic biomaterial exhibiting biochemical and biomechanical properties suitable for load-bearing orthopaedic implants. Two advantages of carbon fibre rei...

Journal: :The Angle orthodontist 2009
Seong-Hun Kim Shin-Jae Lee Il-Sik Cho Seong-Kyun Kim Tae-Woo Kim

OBJECTIVE To test the hypothesis that there is no difference in the stability and resistance to rotational moments of early loaded sandblasted and acid-etched (SLA) mini-implants and those of machined-surface implants of the same size and shape. MATERIALS AND METHODS A randomized complete block design was used in 12 skeletally mature male beagle dogs. Ninety-six orthodontic mini-implants were...

Journal: :The International journal of oral & maxillofacial implants 1998
T Fujimoto A Niimi T Sawai M Ueda

The purpose of this study was to clarify the effects of steroid administration on the osseointegration of pure titanium implants. Twelve female New Zealand white rabbits, 8 weeks of age, were divided into two groups: a prednisolone-treated group (Group P) and a control group (Group C). In each rabbit, two implants were placed into the mandible and two into the tibial metaphyses with bone tappin...

2011
Felipe Miguel SALIBA Mayra CARDOSO Marcelo Ferreira TORRES Alexandre Carvalho TEIXEIRA Eduardo José Veras LOURENÇO Daniel de Moraes TELLES

OBJECTIVES Previous studies that evaluated the torque needed for removing dental implant screws have not considered the manner of transfer of the occlusal loads in clinical settings. Instead, the torque used for removal was applied directly to the screw, and most of them omitted the possibility that the hexagon could limit the action of the occlusal load in the loosening of the screws. The pres...

2013
Eun-Sook Kim Soo-Yeon Shin

PURPOSE This study examined the effects of the abutment types and dynamic loading on the stability of implant prostheses with three types of implant abutments prepared using different fabrication methods by measuring removal torque both before and after dynamic loading. MATERIALS AND METHODS Three groups of abutments were produced using different types of fabrication methods; stock abutment, ...

2014
Seyed Hamid Raji Saeed Noorollahian Seyed Mohsen Niknam

BACKGROUND Primary stability is an important factor for the clinical success of orthodontic mini-screws. The present study made an attempt to evaluate the effect of insertion angle changes on the maximum insertion and removal torque of orthodontic mini-screws. MATERIALS AND METHODS In this experimental study, 72 mini-screws (Dual Top Anchor System, Jeil, 1.6 mm diameter, 8 mm length) were use...

Journal: :Implant dentistry 2012
Liran Levin Shai Frankenthal Hadar Zigdon Marcelo Suzuki Paulo G Coelho

OBJECTIVES To evaluate a novel implant design for immediate implantation. This implant presents a specially designed expanded diameter midcrestal "wing" thread, which is aimed to provide added bone contact for greater insertion torque and primary stability. METHODS Mandibular premolars were extracted in 2 mongrel dogs, and immediate dental implants were inserted into the fresh extraction sock...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید