نتایج جستجو برای: scleral fixation

تعداد نتایج: 55586  

Journal: :American journal of ophthalmology 2001
G T Kokame N H Atebara M D Bennett

PURPOSE To describe a modified technique of haptic externalization during repositioning of dislocated posterior chamber lens implants, which facilitates placement of scleral fixation sutures around the haptic for implant stabilization. METHODS We describe a technique of repositioning a dislocated posterior chamber implant with scleral fixation sutures, which uses a small, clear corneal incisi...

2017
Yong Un Shin Mincheol Seong Hee Yoon Cho Min Ho Kang

PURPOSE To describe a method to overcome the nonavailability of a long needle 9-0 polypropylene suture for sutured scleral fixation of the posterior chamber intraocular lens (PC-IOL) using a single fisherman's knot (SFK). METHODS First, a 10-0 polypropylene suture was passed from the sclera to the ciliary sulcus using a long needle. A 9-0 suture was tied to the unpassed portion of the 10-0 su...

2013
Soosan Jacob Amar Agarwal

Subluxated cataracts secondary to blunt injury are a challenge to treat from the construction of rhexis to IOL insertion. For that reason, we designed a new glued endocapsular ring (ECR)/ segment (ECS) for subluxated cataracts and IOLs for sutureless fibrin glue assisted trans-scleral fixation of the capsular bag. The glued ECR/segment stabilizes the capsular bag intra and post-operatively, all...

2013
Isra Ahmed Bhutto Ghulam Qadir Kazi P.S Mahar Umair Ahmed Qidwai

OBJECTIVE To assess the visual outcome and complications in patients after Ab-externo scleral fixation of intraocular lens in pediatric age group (15 years or less). METHODS This quasi experimental study was conducted at Isra Postgraduate Institute of Ophthalmology, Al-Ibrahim Eye Hospital, Karachi, from January 2012 to December 2012. All cases included were worked up according to the protoco...

2017
Pukhraj Rishi Ekta Rishi Aditya Maitray

PURPOSE To report the outcomes of surgical refixation of posteriorly dislocated intraocular lens (IOL) using scleral-tuck method, and to compare the "scleral groove" and the "scleral flap" techniques used. STUDY DESIGN Single-center, retrospective, interventional, comparative study. METHODS Medical records of patients undergoing closed globe scleral refixation of posteriorly dislocated post...

Journal: :Journal of The Korean Ophthalmological Society 2022

Purpose: We evaluated the utility of peripheral vitrectomy featuring scleral indentation; we compared a group who underwent to control for whom was combined with fixation intraocular lenses (IOLs) in patients exhibiting IOL dislocations.Methods: From January 2018 December 2020, 20 eyes evidencing dislocations that total vitrectomy, removal, and were evaluated; indentation performed 10 patients....

Journal: :Journal of The Korean Ophthalmological Society 2023

Purpose: We compared the surgical outcomes and complications of conventional, sutured scleral fixation flanged intrascleral intraocular lens (IOL) fixation.Methods: retrospectively analyzed medical records patients who underwent or IOL were then observed for more than 6 months. The best-corrected visual acuity (BCVA), operation time, spherical equivalent (SEQ), astigmatism, postoperative record...

2015
Carol P. S. Lam Jason C. S. Yam Flora H. S. Lau Dorothy S. P. Fan C. Y. Wong Christopher B. O. Yu Winnie W. Y. Lau

PURPOSE To evaluate and compare the effectiveness of scleral fixation SR and LR union suture and nonscleral fixation union suture for the treatment of myopic strabismus fixus. METHODS Retrospective review of 32 eyes of 22 patients with myopic strabismus fixus who had undergone union suture of superior rectus (SR) and lateral rectus (LR) with or without scleral fixation, and follow-up longer t...

Journal: :European journal of ophthalmology 2008
G Migliorati P Brusini

PURPOSE To describe a new scleral fixation foldable intraocular lens (IOL): the Ultima. METHODS The novel IOL is a new scleral fixation acrylic hydrophilic foldable lens that offers a 360 degrees sulcus support due to its round geometry. It can be folded and inserted through a 4 mm clear cornea incision. Twenty-five eyes implanted with the Ultima lens were followed for 2 years. RESULTS Twen...

قاسمی فلاورجانی, خلیل, نیک‌اقبالی, امین‌اله, مدرس‌زاده, سید مهدی, ناصری‌پور, مسعود, هاشمی, مسیح, پرورش, محمدمهدی,

    Background & Aim: Several methods have been reported for refixation of dislocated intraocular lenses (IOLs). However, these methods are associated with some disadvantages including vitreous prolaps, vitreous traction, ocular collapse, intraocular hemorrhage, high astigmatism, and the need for complex intraocular maneuvers. The aim of this study was to evaluate the results of transscleral fi...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید