نتایج جستجو برای: selective membrane electrode
تعداد نتایج: 631334 فیلتر نتایج به سال:
چکیده ندارد.
a novel silver (ag) nanocomposite electrode was proposed that fabricated from metal nanostructures and ionic liquids. the combined application of unique properties of nanomaterials and ionic liquids in the design of this ag nanocomposite results in electrodes with interesting advantages compared to the conventional metal disk electrode. in the first part of this thesis, the elecrocatalytic eff...
A PVC-based membrane containing cerium phosphate was developed. Unlike the cerium phosphate itself that acts as a cation exchanger, the membrane exhibited anion-exchange properties. Therefore, the utility of this compound as a sensory element for detection of molybdate ions was pursued. The response of molybdate selective electrode based on this membrane was perfectly linear in the concentr...
in this work we introduce a practical use of synthesized schiff base metal complex in sensing application. a new perchlorate-selective electrode based on the complex n, n'-4-nitro-phenylmethanebis-(salicylaldiminato) copper (ii) [cul] as the membrane carrier was developed. the electrode exhibits a good nernstian slope of -55.0 ± 1.0 mv/decade and a linear range of for perchlorate. the limit o...
a new cesium ion selective pvc membrane based on parent calix [4] arene was developed for potentiometric determination of cesium in environmental samples. the electrode based on p-5,11,17,23tetra(tertbutyl) 25,26,27,28-tetrahydroxy calix[4]arene(thc) as ionophor ,dibutyl phthalate (dbp)as plasticizer ,sodium tetra phenyl borate(natpb)and oleic acid as lipophilic salt and additive showed the bes...
چکیده ندارد.
a new poly(vinylchloride) membrane sensor for cr3+ ions based on di (benzylamino)glyoxime asan ionophore was prepared. the electrode has a linear dynamic range 1×10-6-1×10-1 mol l-1,with anernstian slope of 20.3 ± 0.5 mv per decade and a detection limit of 2×10-7. it has a fast responsetime of
In this work we introduce a practical use of synthesized Schiff base metal complex in sensing application. A new perchlorate-selective electrode based on the complex N, N'-4-nitro-phenylmethanebis-(salicylaldiminato) copper (II) [CuL] as the membrane carrier was developed. The electrode exhibits a good Nernstian slope of -55.0 ± 1.0 mV/decade and a linear range of for perchlorate. The lim...
A PVC membrane Ni(II) ion selective electrode has been constructed using (1E,2E)-bis(2-aminophenyl)N'1,N'2-dihydroxyethanebis as membrane carrier. The electrode exhibited a goodpotentiometric response for Ni(II) over a wide concentration range 1.0×10-4 to 1.0×10-1M with aslope of 29.4±0.5 mV/decade a and a working pH range of 6.5-9.0. It had a fast response time of≤20s. The best performance was...
a new cesium ion selective pvc membrane based on parent calix [4] arene was developed for potentiometric determination of cesium in environmental samples. the electrode based on p-5,11,17,23tetra(tertbutyl) 25,26,27,28-tetrahydroxy calix[4]arene(thc) as ionophor ,dibutyl phthalate (dbp)as plasticizer ,sodium tetra phenyl borate(natpb)and oleic acid as lipophilic salt and additive showed the ...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید