نتایج جستجو برای: semg

تعداد نتایج: 1079  

Journal: :Journal of sports science & medicine 2008
Katja Tomazin Nejc Sarabon Vojko Strojnik

The aim of the study was to find whether voluntary induced high- and low-frequency peripheral fatigue exhibit specific alteration in surface EMG signal (SEMG) during evoked and maximum voluntary contractions. Ten male students of physical education performed 60 s long stretch-shortening cycle (SSC) exercise with maximal intensity and 30 s long concentric (CON) exercise with maximal intensity. T...

2010
PARMOD KUMAR CHANDRASEKHAR POTLURI MARCO P. SCHOEN

Skeletal muscle force can be estimated using surface electromyographic (sEMG) signals. Usually, the sEMG location for the sensors is near the respective muscle motor unit points. Skeletal muscles generate a temporal and spatial distributed EMG signal, which causes cross talk between different sEMG signal sensors. In this paper, an array of three sEMG sensors is used to capture the information o...

2014
Gang Wang Yanyan Zhang Jue Wang

Many attempts have been made to effectively improve a prosthetic system controlled by the classification of surface electromyographic (SEMG) signals. Recently, the development of methodologies to extract the effective features still remains a primary challenge. Previous studies have demonstrated that the SEMG signals have nonlinear characteristics. In this study, by combining the nonlinear time...

2014
Vikram Ravindra Claudio Castellini

In the framework of rehabilitation robotics, a major role is played by the human-machine interface (HMI) used to gather the patient's intent from biological signals, and convert them into control signals for the robotic artifact. Surprisingly, decades of research have not yet declared what the optimal HMI is in this context; in particular, the traditional approach based upon surface electromyog...

Journal: :Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology 2013
Javad Hashemi Evelyn Morin Parvin Mousavi Keyvan Hashtrudi-Zaad

In this paper, a calibration method to compensate for changes in SEMG amplitude with joint angle is introduced. Calibration factors were derived from constant amplitude surface electromyogram (SEMG) recordings from the biceps brachii (during elbow flexion) and the triceps brachii (during elbow extension) across seven elbow joint angles. SEMG data were then recorded from the elbow flexors (bicep...

Journal: :Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology 2011
Simona Tecco Vito Crincoli Beatrice Di Bisceglie Sergio Caputi Felice Festa

This study aimed to evaluate whether there is an association between facial morphology on cephalometrics and surface electromyographic (sEMG) recordings of the head, neck, and trunk muscles. Forty-seven Caucasian adult females, 18-29years of age (average: 24), underwent lateral skull radiographs in "natural head position", obtained by having the subject look at a small mirror at eye level, and ...

2012
Angkoon Phinyomark Pornchai Phukpattaranont Chusak Limsakul

This chapter presents a usefulness of wavelet transform (WT) algorithm in pre-processing stage of surface electromyography (sEMG) signal analysis particularly in application of noise reduction. The successful pre-processing stage based on wavelet decomposition and denoising algorithm is proposed in this chapter together with the principle, theory, up-todate literature review and experimental re...

Journal: :Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology 2015
Simona Tecco Aberto Baldini Stefano Mummolo Enrico Marchetti Maria Rita Giuca Giuseppe Marzo Enrico Felice Gherlone

This study aimed to assess by surface electromyography (sEMG) the changes in sub-mental, orbicularis oris, and masticatory muscle activity after a lingual frenulectomy. Rehabilitation exercises in subjects with ankyloglossia, characterized by Class I malocclusion, were assessed as well. A total of 24 subjects were selected. Thirteen subjects (mean age 7±2.5years) with Class I malocclusion and a...

2017
Rebekah L S Summers Mo Chen Teresa J Kimberley

OBJECTIVES Muscular targets that are deep or inaccessible to surface electromyography (sEMG) require intrinsic recording using fine-wire electromyography (fEMG). It is unknown if fEMG validly record cortically evoked muscle responses compared to sEMG. The purpose of this investigation was to establish the validity and agreement of fEMG compared to sEMG to quantify typical transcranial magnetic ...

Journal: :Advances in experimental medicine and biology 2011
Joachim Taelman Joke Vanderhaegen Mieke Robijns Gunnar Naulaers Arthur Spaepen Sabine Van Huffel

This study looks at various parameters, derived from surface electromyography (sEMG) and Near Infrared Spectroscopy (NIRS) and their relationship in muscle fatigue during a static elbow flexion until exhaustion as well as during a semidynamic exercise.We found a linear increasing trend for a corrected amplitude parameter and a linear decreasing slope for the frequency content of the sEMG signal...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید