نتایج جستجو برای: soft tissue phantom

تعداد نتایج: 1011597  

Journal: :Journal of biomechanics 2012
Gwladys E Leclerc Laëtitia Debernard Félix Foucart Ludovic Robert Kay M Pelletier Fabrice Charleux Richard Ehman Marie-Christine Ho Ba Tho Sabine F Bensamoun

The purpose of this study was to create a polymer phantom mimicking the mechanical properties of soft tissues using experimental tests and rheological models. Multifrequency Magnetic Resonance Elastography (MMRE) tests were performed on the present phantom with a pneumatic driver to characterize the viscoelastic (μ, η) properties using Voigt, Maxwell, Zener and Springpot models. To optimize the...

2016
Sasithorn Amnuaywattakorn Chanika Sritara Chirawat Utamakul Wichana Chamroonrat Arpakorn Kositwattanarerk Kanungnij Thamnirat Boonsong Ongphiphadhanakul

BACKGROUND Trabecular bone score (TBS), which has been proposed to be used in complementary with bone mineral density (BMD) to improve the assessment of fracture risk, is negatively associated with body mass index (BMI). The effect of soft tissue, which is expected to be thicker in subjects with high BMI, on TBS was studied using three scan types: Hologic with fast array mode (Hfa), Hologic wit...

2017
Georgios Menikou Christakis Damianou

BACKGROUND This study describes a series of experimental work completed towards characterizing candidate materials for fabricating brain and muscle tissue mimicking phantoms. METHODS The acoustic speed, attenuation, impedance, thermal diffusivity, specific heat and thermal conductivity were measured. RESULTS The resulting brain (2% w/v agar-1.2% w/v Silica Dioxide-25%v/v evaporated milk) an...

2014
Mahdi Ghorbani Fateme Salahshour Abbas Haghparast Toktam Ahmadi Moghaddas Courtney Knaup

PURPOSE The aim of this study is to compare the dose in various soft tissues in brachytherapy with photon emitting sources. MATERIAL AND METHODS (103)Pd, (125)I, (169)Yb, (192)Ir brachytherapy sources were simulated with MCNPX Monte Carlo code, and their dose rate constant and radial dose function were compared with the published data. A spherical phantom with 50 cm radius was simulated and t...

A. Nickfarjam, B. Farhood, M. Bakhshandeh, R. Abedi Firouzjah,

Background: This study aimed to evaluate the dose calculation accuracy of EclipseTM treatment planning system (TPS) in a heterogeneous chest phantom with the intensity modulated radiotherapy (IMRT) technique using EBT3 film and Delta4. Materials and Methods: Two IMRT plans (A and B) were prepared for radiotherapy of the heterogeneous chest phantom. Plan A was between the left lung and the surro...

Journal: :acta medica iranica 0
khodamorad jamshidi department of orthopaedic surgery, tehran university of medical sciences, tehran, iran. iman qomashi department of orthopaedic surgery, tehran university of medical sciences, tehran, iran. mehdi ramezan shirazi department of orthopaedic surgery, tehran university of medical sciences, tehran, iran.

lipoma is the most common soft tissue tumor but the presence of osseous component within the tumor is quite rare. some studies show that less than 1% of lipomas were ossified. we describe the histological, radiological and diagnostic features of an ossified intramuscular lipoma. to the best of the authors' knowledge, a symptomatic ossified intramuscular lipoma without any cortical erosion and h...

2017
Chunhao Wang Fang-Fang Yin W. P. Segars Zheng Chang Lei Ren

PURPOSE To develop a 4-dimensional computerized magnetic resonance imaging phantom with image textures extracted from real patient scans for liver motion studies. METHODS The proposed phantom was developed based on the current version of 4-dimensional extended cardiac-torso computerized phantom and a clinical magnetic resonance scan. Initially, the extended cardiac-torso phantom was voxelized...

2009
Hamed Ajabi Naeeni

Dynamic shear test on simulated phantom can be used to validate magnetic resonance elastography (MRE) measurements. Phantom gel has been usually utilized for the cell culture of cartilage and soft tissue and also been used for mechanical property characterization using imaging systems. The viscoelastic property of the phantom would be important for dynamic experiments and analyses. In this stud...

Journal: :Journal of Bionic Engineering 2021

Abstract The fabrication of multi-material medical phantoms with both patient-specificity and realistic mechanical properties is great importance for the development surgical planning training. In this work, a 3D printing system phantom manufacturing was developed. Rigid elastomeric materials are firstly combined in such application an accurate tactile feedback. designed multiple layers, where ...

Journal: :iranian journal of otorhinolaryngology 0
ali ebrahimi department of dermatology, kermanshah university of medical sciences, kermanshah, iran. mohammad radmanesh department of dermatology, jondishapour university of medical sciences, ahwaz, iran. sohrab rabiei department of otolaryngology, kermanshah university of medical sciences, kermanshah, iran. hossein kavoussi department of dermatology, kermanshah university of medical sciences, kermanshah, iran.

introduction: the phenomenon of neglected foreign bodies is a significant cause of morbidity in soft tissue injuries and may present to dermatologists as delayed wound healing, localized cellulitis and inflammation, abscess formation, or foreign body sensation. localization and removal of neglected soft tissue foreign bodies (stfbs) is complex due to possible inflammation, indurations, granulat...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید